Appendix
C
Accessory Installation Guide
RACK MOUNT INSTALLATION
KIT 09895-88022
WARNING
LIVE VOLTAGES ARE EXPOSED INSIDE FLEXIBLE DISC
MEMORY. DISCONNECT POWER BEFORE BEGINNING IN-
STALLATION. ALSO, UNIT WEIGHS BETWEEN 45 AND 60
POUNDS (20 AND 27 KG). BE CAREFUL WHEN LIFTING.
CAUTION
DON'T PLACE THE UNIT ON THE FRONT SURFACE, AS THE
DOOR HANDLES EXTEND BEYOND THE FRAME.
CAUTION
FLEXIBLE DISC MEMORY CANNOT BE SUPPORTED BY
FRONT PANEL ONLY. THE RACK MOUNT INSTALLATION
MUST HAVE SIDE SUPPORT RAILS.
1. Remove power and interface cables from rear panel connectors.
2. Open the drive doors and pull at points A and B (as shown in Figure C-1) to remove
the front panel.
3. Place the unit on a broad, flat object (such as a book), so that the feet are off the
surface.
4. Remove the four recessed screws (two per side) on the exposed front panel as shown
in Figure C-2. Keep the screws and washers for mounting into the rack.
5. Remove the cover-securing screw in each of the lower corners on the rear of the unit.
6. Slide the cover back and off of the unit.
7. Install the top plate, being careful to slide the front edge of the top plate into the slot in
the front panel bezel. Secure the top plate with the four screws provided. Install the
two screws removed in step #5 into the same holes from which they were removed.
8. Install side rails into rack and secure. For HP 294008 Series racks order Accessory
#126798. Do not use slide brackets for mounting.
9. Place the unit in the rack and secure it to the rack using the screws and washers
removed in step #4 into the same recessed holes shown in Figure C-2. Again, do not
support the unit by the front panel only. The rack must have a shelf or side rails.
10. Snap in the front panel.
C-1