P36D-10 Gas Fireplace

Horizontal or Vertical Terminations

The minimum components required for a basic horizontal termination are:
1
Horizontal Termination Cap
1
90
Elbow
o
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness (see chart)
Wall thickness is measured from the back standoffs to the inside mounting
surface of termination cap. For siding other than vinyl furring strips may be
used, instead of the vinyl siding standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure
to outside surface of wall without siding and add 2 inches.
Alternate
Horizontal Termination
Caps
WARNING:
Do not combine venting components from
different venting systems.
However use of the AstroCap
Regency Riser is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent , Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.
The Regency AstroCap
and Regency Riser Vent terminal are certified for installations using Regency venting systems as well as Simpson
TM
Dura-Vent
Direct Vent , American Metal Products Ameri Vent Direct Vent, Security Secure Vent
®
trademark of Regency Fireplace Products. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

RIGID PIPE VENTING SYSTEMS

Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
and
TM
Gas Fireplaces
Flat Wall Installation
Wall Thickness
(inches)
4" - 5-1/2"
7" - 8-1/2"
10" - 11-1/2"
9" - 14-1/2"
15" - 23-1/2"
Wall Thickness
(inches)
3-1/4" - 6-3/4"
7-3/4" - 16-1/4"
7-1/4" - 8-3/4"
4-1/4" - 5-3/4"
Vinyl Siding
Standoff (Optional)
Adj.Pipe Length
11" - 14-5/8"
90 Elbow
o
24" Pipe
Length
Rigid Pipe Adaptor
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
, Selkirk Direct-Temp. AstroCap
®
Vent Length Required
(inches)
6"
9"
12"
11" - 14-5/8" Adj. Pipe
17" - 24" Adj.
Corner Installation
Vent Length Required
(inches)
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
6" + 12"
9" + 9"
6" + 9"
Horizontal
Termination
Wall Thimble
is a proprietary
TM
Cap

Advertisement

Table of Contents