Timing And Synchronization Function And Performance Indexes; Frequency Accuracy; Frequency Capture And Out-Of-Lock Range; Synchronization Clock Source - Zte ZXA10 S300 Technical Manual

Integrated access service dispatching unit
Table of Contents

Advertisement

Timing and Synchronization
Function and Performance
Indexes

Timing and synchronization function and performance indexes

contain:

Frequency Accuracy

Frequency Capture and Out-of-lock Range

Synchronization Clock Source

Switching of Reference Clock
Output of Timing Reference
Some Electrical and Physical Features of Timing Interfaces
Wander and Jitter Indexes of Timing Reference Interface
Timing Interface Extension Function
Number of Clock Concatenations
Frequency Accuracy
The output frequency accuracy during the free run of the NE
clock is better than +4.6 × 10
The frequency stability in the holdover mode is: Frequency
deviation ≤ 0.37 × 10
Frequency Capture and Out-of-lock
Range
The minimum frequency capture and out-of-lock range are: ±4.6
-6
× 10
.
Synchronization Clock Source
It can be obtained from the following types of input:
2,048 kHz synchronization clock input and 2,048 kbit/s
synchronization clock input. 2,048 kbit/s is preferred as the
default upon power-on. The 2,048 kbit/s synchronization
clock signal complies with Recommendation G.704.
Recover timing from the STM-N signals.
Confidential and Proprietary Information of ZTE CORPORATION
-6
.
−6
. (20 ∼ 30°C) 24 hours.