SITE SELECTION: ProCure™ 750 UV CHAMBER
Locating the ProCure 750 UV Chamber is similar in many respects to the ProX 800. The following abbreviated site specifications
are for the ProCure UV Chamber:

ProCure SPACE AND LOCATION SELECTION

The ProCure UV Chamber should be located in an appropriate room or location adjoining the ProX 800 . Refer to the illustration,
"Optimal Site Layout" on page 3
Components" on page 10
for weights and measurements, as well as the illustration,
on page
9. Consider the following additional specifications when selecting the location for your ProCure unit:
Recommended floor space
Minimum ceiling height
Recommended ceiling height
Recommended clearance to ceiling

ProCure FLOOR SURFACE REQUIREMENTS

Flooring under the ProCure UV Chamber should be non-porous and suitable for
cleaning with solvents. Carpeted floors are not recommended.

ProCure ELECTRICAL REQUIREMENTS

Specification - either of these two power configurations:
110 VAC, 50/60 Hz, 13A
220 VAC, 50/60 Hz, 7A
The ProCure UV Chamber is equipped with a standard IEC 60320 C14 3-wire
power cord inlet, and a USA plug with an IEC 60320 C13 outlet .
Electrical power for the ProCure UV Chamber must be on a dedicated, surge
protected circuit . We strongly recommend an Uninterruptible Power Supply
(UPS) in areas with frequent power fluctuations; surges and spikes can damage
electronic components and power loss can damage the unit .

ProCure VENTILATION (DUCTWORK)

The ProCure UV Curing Chamber may be vented outside if required or appropriate . The left side of the unit has a built-in
exhaust fan, and includes an 8" diameter duct connector .
If the curing chamber duct is joined to a duct that has positive pressure, an extraction system should be installed, regardless
of duct length . Flow restriction from a 90 degree elbow equals 5 .1 m (17 ft) of duct . If the exhaust run exceeds the 60 m (200 ft)
limit, an extraction system or auxiliary fan should be installed . Contact your Facilities Manager for your requirements .
Caution: Never disconnect a ducting system that is connected to an external extraction system .
3D Systems, Inc.
for a suggested overall layout . Refer to the table,
7 m x 4 .5 m 12 ft x 15 ft
244 cm
96 in
305 cm
120 in
76 cm
30 in
"Weight and Dimensions - System
"ProCure 750 UV Chamber Dimensions"
IEC 60320 C13 connector and C14 inlet are
rated 10A (VDE) and 15A (UL & CSA)