ALTITUDE
The SLA system is capable of operating correctly up to an altitude of 1000m above mean sea level .
OVERALL SOUND PRESSURE LEVEL (OASPL)
The sound of the SLA system will not exceed 70 dBA .
AIR CLEANLINESS
The room housing the SLA system should be well ventilated . Reasonable care should be taken to minimize dust and smoke
which could contaminate the material and cause deterioration of optical surfaces. Avoid temperature fluctuation. Since dust,
smoke and temperature fluctuations can affect the performance of the machine and the quality of the parts, a restricted area
with positive pressure filtered air flow is recommended. Avoid proximity to machine shop areas, or where milling, grinding, or
sanding is performed .
LIGHTING
Standard fluorescent lamps with clear plastic diffusers are recommended to minimize ultraviolet exposure, which could
negatively affect the printing material . Sunlight, quartz-halogen lamps, and high-intensity incandescent lamps are not suitable,
and UV-intensive lighting or ultraviolet exposure through windows should be avoided. UV filters are available for windows and
exposed fluorescent lamps.
DOOR OR OTHER METHOD OF PREVENTING ACCESS TO ROOM
The site should be able to be isolated from other employees or personnel during installation or future service calls . A separate
room or area that can be closed to others is necessary . The system is safe and does not present hazards to properly trained
personnel operating the system in accordance with our specifications. However, the system should be installed in an area that
can be cleared of untrained personnel during service and maintenance of the machine due to laser safety requirements .
NETWORK ACCESS
The SLA system controller computer includes a Class A Ethernet interface, which can be connected to a 10/100/1000 Gigabit
Ethernet network to offer network access to the SLA system . A cable that is 6 m long is supplied with the ProX 800 . To remotely
operate the ProX 800 or to remotely run service engineer diagnostics, a VPN network access is required .
7
3D Systems, Inc.