Configuring Maximum Self-consumption

This section describes the StorEdge applications and how to configure the system per application.

Maximize Self-consumption

In this mode, the battery is automatically charged and discharged to meet consumption needs. 
The battery has two states:
 
OFF – the battery is in standby
l
 
ON – the battery is controlled for maximized self-consumption
l
Battery OFF periods can be configured to extend battery lifetime by minimizing the number of shallow 
discharges (for example at nighttime or during the winter). 

Profile Programming (for time of use arbitrage)

In this mode, the StorEdge system operates according to a configured charge/ discharge profile.  This  
application is covered in a separate application note available at 
http://www.solaredge.com/files/pdfs/StorEdge_TOU_profile_programming.pdf.
To set up max. self-consumption:
 1.  Enter Setup mode, scroll down to the Power Control menu and select it. A menu similar to the 
following is displayed:
G r i d
E n e r g y
R R C R
R e a c t i v e
A c t i v e
P h a s e
W a k e u p
P ( f )
A d v a n c e d
L o a d
 2.  Select Energy Manager. The following screen is displayed:
L i m i t
E n e r g y
Limit Control: For power limitation (including export limitation) configuration. This option can be 
used in parallel to energy control. For more information refer to 
http://www.solaredge.com/files/pdfs/products/feed-in_limitation_application_note.pdf. 
Energy Control: The method by which to manage the energy. 
 3.  Select Energy Ctrl.. The following is displayed, showing the SolarEdge applications:
M a x
T i m e
D i s a b l e
Max Self-consume (MSC): Maximize Self-consumption .
Time of Use (TOU): Profile Programming.
Disable: No energy control, that is, the battery is not used.
SolarEdge-StorEdge Installation Guide MAN-01-00249-1.2
C o n t r o l
< E n >
M a n a g e r
C o n f .
P w r
C o n f .
P w r
C o n f .
B a l a n c e
< D i s >
C o n f .
D e f a u l t s
C o n t r o l < D i s >
C t r l
< D i s >
S e l f - c o n s u m e
o f
U s e
Chapter 4: System Configuration