Configuring The Rs485 Bus For Battery And Meter Connection - SolarEdge StorEdge Installation Manual

For smart energy management using the storedge interface
Hide thumbs Also See for StorEdge:
Table of Contents

Advertisement

Configuring the RS485 Bus for Battery and Meter
Connection
This section describes how to set up the RS485 communication between the       i nverter, meter, StorEdge 
Interface, and battery.
To configure the RS485 bus:
 1. Select Communication è RS485-1 Conf è Device Type è Multi Devices. A list of devices is 
displayed.
D e v i c e
M e t e r
M e t e r
B a t t e r y
 2. Select Meter 2. The meter configuration screen is displayed:
D e v i c e
P r o t o c o l
D e v i c e
C T
R a t i n g
M e t e r
 3. Configure the meter:
 a. Select Device Type è Revenue Meter
 b. Select Protocol è WattNode
 c. Verify that Device ID is set to  2.
 d. Set the CT value that appears on the CT label: CT Rating è <xxxxA>.
If CT resets to 0, check the communication as descibed in step b below.
 e. For a meter installed st the grid connection point select Meter Func.è Export+Import.
E x p o r t + I m p o r t
E x p o r t
C o n s u m p t i o n
P r o d u c t i o n
I m p o r t
N o n e
The selected option is displayed in the RS485 Conf screen as <E+I>.
 4. Select Battery 1. The battery configuration screen is displayed:
D e v i c e
P r o t o c o l
D e v i c e
B a t t e r y
 5. Select Device Type è Battery Pack.
SolarEdge-StorEdge Installation Guide MAN-01-00249-1.2
T y p e
< M L T >
1
< - - - >
2
< - - - >
1
< - - - >
T y p e
< M T R >
< W N >
I D
< 2 >
< 0 >
F u n c .
< N o n e >
T y p e
< B A T >
< T 7 4 >
I D
< 2 4 >
I n f o
<
>
Chapter 4: System Configuration