Error Display In Onecontrol Touch Panel Or One Control App - Lippert Components ground control TT Owner's Manual

Leveling hd & se with onecontrol touch panel
Hide thumbs Also See for ground control TT:
Table of Contents

Advertisement

Error Display In OneControl Touch Panel or One Control App

NOTE: Errors can only be cleared via the OneControl Touch Panel or OneControl Leveling App through
MyRV®. The only exception is when the Auto Leveling Control Touch Panel (Fig. 3) was used to abort
an auto-sequence. In this case the error can be cleared by pressing any Auto Leveling Control button.
NOTE: To clear an error from the OneControl Touch Panel or the OneControl App, correct the issue, then
press "OK." If the error is still present, the message will be displayed again.
Touch Panel
Message
"EXCESS ANGLE"
"EXCESSIVE ANGLE"
"BAD CALIBRATION"
"FEATURE DISABLED"
"LOW VOLTAGE"
"OUT OF STROKE"
"EXTERNAL SENSOR"
"JACK TIME OUT"
"AUTO LEVEL FAIL"
"FUNCTION ABORTED"
"HALL POWER SHORT"
"CAN'T COMPLETE
LEVEL IN THIS
LOCATION. PLEASE
RELOCATE RV TO
FLATTER TERRAIN"
Rev: 11.13.2017
What's Happening?
Unsecured controller.
Uneven or sloped site.
Excessive angle reached during
manual operation.
Trailer zero point was not set
correctly.
Hitch recognition requested but no
hitch height set.
Zero point not set.
Bad connection or wiring.
Discharged or bad battery.
Unsecured controller.
Uneven or sloped site.
Bad connection or wiring.
System could not level in expected
time.
Unsecured controller.
Voltage drop.
User has aborted an automatic
leveling sequence.
Short circuit detected on one or
more of the jack hall effect power
lines.
The trailer is parked on a steep
incline during auto level. The front
cannot be leveled and the front jacks
are already fully retracted.
What Should I Do?
Check and secure controller placement.
Relocate the trailer.
Stop manual operation and reset jacks to
a more level state. The code will self clear,
there is no need to hit "OK."
Reset zero point.
Perform "AUTO LEVEL" sequence to
establish hitch height.
Set zero point.
Check wiring - repair or replace.
Test battery voltage under load - charge or
replace.
Check and secure controller placement.
Relocate the trailer.
Replace or repair connection to rear remote
sensor.
Check disposition of jacks.
Check and secure controller placement.
Test battery voltage under load - charge or
replace.
Restart the sequence.
Check harness and replace or repair.
Relocate the trailer.
Page 18
Ground Control TT Leveling OCTP Owner's

Advertisement

Table of Contents
loading

Table of Contents