Alvarion BreezeACCESS VL 5.4 System Manual page 122

Breezeaccess vl series
Table of Contents

Advertisement

A-2
d.
Gateway Address.
5.
To verify the connection, PING the unit's IP address and verify that
PING replies are being received.
6.
Use the TFTP utility, with the following syntax, to perform the
upgrade:
tftp –i hostaddress put sourcefile [destinationfile]
where
unit to be upgraded.
hostaddress.
7.
Use the SNMP write community <SnmpWriteCommunity>.dwn to
define the destination filename. The default write community is
private. For example, to load the upgrade file au1_0_6.bz to an AU
whose IP address is 206.25.63.65:
tftp –i 206.25.63.65 put au1_0_6.bz private.dwn
8.
When the loading is complete, the following message is displayed:
Download operation has been completed successfully
9.
The FLASH memory can store two software versions. One version is
called Current and the second version is called Shadow. The new
version is loaded into the Shadow (backup) FLASH memory. To check
that the new firmware was properly downloaded, view the firmware
versions stored in the FLASH, as follows:
a.
b.
c.
Versions. The following information is displayed:
Flash Versions
===========
Running from
Main Version
Shadow Version
To configure the default gateway address, select 3 - Default
-i
is for binary mode and
put
causes the PC client to send a file to the
destinationfile
is the name of the file to be loaded.
From the Main Menu, select 2 – Unit Control.
From the Unit Control menu, select 5 – Flash Memory Control.
From the Flash Memory Control menu, select S – Show Flash
BreezeACCESS VL System Manual
hostaddress
is the IP address of the
:main version
:
au1_0_5.bz
:
au1_0_6.bz