Standard 25

Select Message Length

It is used to program the valid reading length of Standard 25. The engine will
not send barcode message to the Host, if the decoded data length does not
match the valid length.
Standard 25 Message Length is defined by "Min. Message Length" and
"Max. Message Length ."
Min Message Length (default: 6)
【Pro CMD:0418030】
1D bar code Message Length should not exceed 127 bytes. If Max Message Length is
less than Min Message Length, it means the engine will only support barcodes of the two
lengths. If Max Message Length is equal to Min Message Length, the engine will only sup-
port barcodes of the length.
To set Min Message Length of Standard 25 to 8 bytes and Max Message Length to 12
bytes, read these programming codes:
1."Code Programming ON"
2."Select Min Message Length"
3. Digit Code "8", see Digit Code
4."Save Programming", see Digit Code
5."Select Max Message Length"
6. Digit Code "1"
7. Digit Code "2"
8."Save Programming"