Mitel MiVoice 6900 Series IP Phones - Release 1.1 Administrator Guide
3. Click on Diagnostics.
4. Click on the Enable button beside Automatic upload.
Set syslog level
To set the syslog (system log) level:
1. In the Syslog Level drop-down list, select the log level.
2. Click on the Save button.
Note: The log collected through external application, for example IP Phone Analyzer (IPA), is
based the log level selected in the Syslog Level drop-down list. For example, if the Syslog
Level is set to TRACE, then the IPA can set the log level to TRACE, WARN and so on, and
receive logs based on the set log level. If the Syslog Level is set to WARN, then the highest
log level IPA can set is WARN. TRACE level logs will not be available.

Screenshot

The Screenshot option allows you to capture a screenshot image of what is currently displayed on
the respective IP phone's LCD screen in PNG format. This can be used to help document the
procedures leading up to an issue or help in identifying issues with the UI.
To take a screenshot:
1. Open your web browser and enter the phone's IP address or host name into the address bar.
2. Enter your username and password and click OK/Login.
The status window displays for the IP phone you are accessing.
Note: The default username is "root" and the default password is "73738".