Rear panel switches and connectors

Configuration switches

All switches are hardware controlled and a change to any switch setting is effective immediately.

Configuration switch functions

Switch number
Function
1
HALT polarity
2
Head LED control
3
STOP disabled
4
SYNC polarity
5
Audible indicator
6
Debounce time
7
Debounce mode
8
Zero debounce
9
Probe signal filter
10
Trigger level
11
PDAMP / HALT filter delay
12
PDAMP / HALT filter delay
13
Probe polarity reversal
Switch 1:
Inverts the polarity of the HALT output.
Issued 01 2018
Switch position
Description
UP
HALT active HIGH
DOWN
HALT active LOW
UP
External control via PICS
DOWN
LED mimics SYNC
UP
PI 200-3 ignores PICS - STOP
DOWN
STOP asserts HALT/SYNC
UP
SYNC HIGH and SSR closes on trigger
DOWN
SYNC LOW and SSR opens on trigger
UP
No beep on trigger
DOWN
Indicator beeps on trigger
Selects SYNC debounce time
Selects SYNC debounce mode
UP
Sets debounce time <2 ms
DOWN
Debounce set by switches 6 and 7
UP
Filter active
DOWN
Filter off
UP
Trigger level 2 selected
DOWN
Trigger level 1 selected
Coded to select delay time
Coded to select delay time
Refer to table 3
UP
Reversed
DOWN
Normal