Rear Panel Rs485 Out Connector - TDK-Lambda G10-500 User Manual

Genesys series programmable dc power supplies 5kw in 1u 0- 600v/ 0-500a
Hide thumbs Also See for G10-500:
Table of Contents

Advertisement

5.4

Rear Panel RS485 OUT Connector

RS485 OUT interface is accessible through the Rear panel RS485 OUT connector. The connector
is eight contacts, shielded RJ-45 type. The connector is used to connect power supplies in RS485
Daisy chain configuration. Refer to Figure 5–2 for the connector description.
RS485 OUT Pinout:
1.
NC (Not Connected)
2.
NC (Not Connected)
3.
RS485 TXD-
4.
RS485 RXD-
5.
RS485 RXD+
6.
RS485 TXD+
7.
NC (Not Connected)
8.
SG (Signal Ground)
TXD +/- and RXD +/- are used for RS485 communication. Refer to RS232 (Figure 5–3) and
RS485 (Figure 5–4) cable descriptions for connection details.
(Connector enclosure)
1 2 3 4 5 6 7 8
Figure 5–2: J3 Rear Panel RS485 OUT Connector Pinout
Shield
NOTE
55