Rear Panel In/Out Connector Pins Function Description - TDK-Lambda RFE2500 Series Instruction Manual

Table of Contents

Advertisement

1.4

Rear Panel IN/OUT Connector Pins Function Description

J1 – Main Connector
Pin #
Function
J1-1, J1-15
-SENSE
J1-2
+SENSE
VOLTAGE
J1-3
PROGRAMMING
CURRENT
J1-4
PROGRAMMING
J1-5
V_REF
J1-6
TEMP ALARM
J1-7
DC OK
J1-9
ENABLE
J1-8, J1-10,
SIGNAL RETURN
J1-19
J1-11
Local -SENSE
J1-12
Local +SENSE
J1-13
TRIMMER
J1-14
+5V
J1-16
AC FAIL
J1-17,J1-18
CURRENT SHARE
J1-20
+12V AUX OUT
J2 - Optional PMBus interface
J2-1, J2-2,
A2, A1, A0
J2-3
(optional PMBus)
J2-4
Remote (-) SENSE
SMB ALERT
J2-5
(optional PMBus)
SDA
J2-6
(optional PMBus)
SCL
J2-7
(optional PMBus)
J2-8
SIGNAL RETURN
TB
TB-1
AC LINE
TB-2
AC NEUTRAL
TB-3
PROTECTIVE GROUND AC GROUND. Refer to Section 2.1 for Safety Instructions.
Negative sense.
The -SENSE signal should be connected to -V on Power Supply or Load side.
Positive sense.
The +SENSE signal should be connected to +V on Power Supply or Load side.
Input 0~5V. Provides Vout programming by Voltage.
Refer to Section 3.2.4, Section 3.2.5 and Section 3.2.6.
Input 0~5V. Provides Current programming by Voltage.
Refer to Section 3.2.7 and Section 3.2.8.
Variable when Voltage/Current programming is done with PMBus option. Refer
to Instruction Manual
TEMP ALARM signal. LOW when the internal temperature is within safe limit;
HIGH approx. 10°C below Thermal shut down. Open collector type (15V, 10mA).
DC OK signal. LOW when the output voltage is higher than 85~95% of Vout set.
Open collector type (15V, 10mA).
Turns ON the main output by electrical signal or dry contact (0~0.6v or short).
Return for the following control signals: ENABLE supervisory signals TEMP
ALARM, AC FAIL, AUX and PMBus signals: SCL, SDA, SMB ALERT,
SIGNAL RETURN and mentioned signals are isolated from the output terminals
and -SENSE.
Negative Output Voltage (Can't supply load current)
Positive Output Voltage (Can't supply load current)
Refer to Section 3.2.4.
5V fix output for standard option unit.
AC FAIL Signal; LOW when the input voltage is 85Vac<Vin<270Vac;
HIGH when the input voltage is Vin<85Vac or Vin>270Vac.
Open collector type (15V, 10mA).
Current sharing signal should be connected when Power Supplies are connected
in parallel to allow accurate current share between units.
11.2~12.5V Auxiliary Voltage Output. Maximum load current is 0.5A.
This output has a built in O-Ring diode.
Not affected by the ENABLE signal or any other fault.
PMBus Address lines. Refer to the PMBus interface description RFE Instruction
Manual Section 5.1.3.
Negative sense.
PMBus INTERRUPT signal.
Refer to the PMBus interface description RFE Instruction Manual.
Serial Data signal.
Refer to the PMBus interface description RFE Instruction Manual.
Serial Clock signal.
Refer to the PMBus interface description RFE Instruction Manual.
Return for the following control signals: ENABLE supervisory signals TEMP
ALARM, AC FAIL, AUX and PMBus signals: SCL, SDA, SMB ALERT,
SIGNAL RETURN and mentioned signals are isolated from the output terminals
and -SENSE.
AC LINE. Refer to Section 2.1 for Safety Instructions.
AC NEUTRAL. Refer to Section 2.1 for Safety Instructions.
Table 1-1: Rear panel IN/OUT pins
Figure 1–7: IN/OUTPUT CONNECTORS
Description
6
Referenced to
-SENSE
+SENSE
-SENSE
-SENSE
-SENSE
SIGNAL RETURN
SIGNAL RETURN
SIGNAL RETURN
-V
+V
-SENSE
-SENSE
SIGNAL RETURN
-SENSE
SIGNAL RETURN
-SENSE
-SENSE
SIGNAL RETURN
SIGNAL RETURN
SIGNAL RETURN
SIGNAL RETURN