TDK-Lambda G10-500 User Manual page 125

Genesys series programmable dc power supplies 5kw in 1u 0- 600v/ 0-500a
Hide thumbs Also See for G10-500:
Table of Contents

Advertisement

[SOURce]:VOLTage:SLEW:DOWN <NRf+>
Function
Sets a digital voltage reference down programming slew rate.
Parameters
0.0001 ~ 999.99
Unit
V/mS
Query
[SOURce]:VOLTage:SLEW:DOWN?
Return
<NR2>
Example
:VOLT:SLEW:DOWN 1 Sets a digital voltage reference down programming
slew to 1V/mS.
:VOLT:SLEW:DOWN? returns a digital voltage down programming slope
value.
:VOLT:SLEW:DOWN? MAX, and :VOLT:SLEW:DOWN? MIN return the
maximum and minimum digital voltage reference down programming slope
value.
[SOURce]:VOLTage:SLEW:UP <NRf+>
Function
Sets a digital voltage reference up programming slew rate.
Parameters
0.0001 ~ 999.99
Unit
V/mS
Query
[SOURce]:VOLTage:SLEW:UP?
Return
<NR2>
Example
:VOLT:SLEW:UP 1 Sets a digital voltage reference up programming slew to
1V/mS.
:VOLT:SLEW:UP? returns digital voltage up programming slope value.
:VOLT:SLEW:UP? MAX, and :VOLT:SLEW:UP? MIN return the maximum
and minimum digital voltage reference up programming slope value.
[SOURce]:VOLTage:MODE <DSC>
Function
Sets the voltage programming mode.
Parameters
0|1|2, NONE|LIST|WAVE
Query
[SOURce]:VOLTage:MODE?
Return
<DSC> NONE|LIST|WAVE
[SOURce]:VOLTage:PROTection:LEVel <NRf+>
Function
Sets a voltage protection level (OVP).
Parameters
The range is limited by the OVP programming range and voltage
programmed value. Minimum setting level is about 105% of the
programmed voltage value.
Unit
V
Query
[SOURce]:VOLTage:PROTection:LEVel?
[SOURce]:VOLTage:PROTection:LEVel? MAX
[SOURce]:VOLTage:PROTection:LEVel? MIN
Return
<NR2> 4-digits format
117

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G10-500 and is the answer not in the manual?

Table of Contents

Save PDF