The recovery options available are:
Upgrade Software Image:This allows the user to reload a software image. This may be the
original image if software corruption is suspected or a step back to an old image if an incorrect
image has just been loaded.
Reset IP and Ethernet Configuration back to factory defaults:This allows the user to
reset the unit back to the factory defaults:
IP Address 169.254.1.1 (or 10.10.10.10)
Netmask 255.255.0.0
Gateway 169.254.1.0
Ethernet Interface Auto-negotiate, Auto-MDI/MDIX
Erase Configuration:This allows the user to erase the unit's entire configuration. Executing this
option will also erase factory settings such as target MAC address, range setting, license key, etc.
Zeroise Critical Security Parameters:This allows the user to erase the security parameters
such as AES parameters. This is to comply with FIPS requirements.
Reboot:This allows the user to reboot the unit. This option must be executed after resetting the
IP and Ethernet configuration or erasing the configuration detailed above.
Software Version:This is the software version of the recovery operating system permanently
installed during manufacture.
Recovery Mode
Figure 81 Recovery Options Page