Page 2
Inc. reserves the right to make changes to any products described herein and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Motorola, Inc. does not assume any liability arising out of the application or use of any product, software, or circuit described herein;...
This Read-me-first document describes a summary of changes between the existing SC 4812T BTS and the SC 4812T-MC (Multicarrier) BTS. The SC 4812T-MC is based on the existing SC 4812T platform and employs similar hardware and architecture. The differences between these products are briefly described and illustrated below.
Page 4
ETHERNET ROUTER (IF USED; EXP IN FILLER RF EXPANSION PORT TO ANOTHER (TO ANOTHER BTS) OTHERWISE, FILLER PLATE) PLATE BTS (USED ONLY IF EXPANSION FRAME INSTALLED; OTHERWISE, FILLER PLATE INSTALLED) ti-CDMA-WP-00101-v01-ildoc-ftw ti-CDMA-WP-00188-v01-ildoc-ftw RMF-2 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
Page 5
IMPORTANT: A breaker supports a pair of PAs. In SC4812T–MC, disengaging (pulling) a PA breaker while the BTS is operational will degrade the TX Output power of ALL sector–carriers, not just a specific carrier as in SC4812T. Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP RMF-3...
SC 4812T-MC BTS READ-ME-FIRST (Optimization/ATP) 68P64115A21–B SC 4812T-MC BTS READ-ME-FIRST (Optimization/ATP) General Test Procedural Changes in SC 4812T-MC NOTE The GENERAL information herein summarizes procedural changes introduced with the SC 4812T–MC BTS. Detailed procedures are provided in the Optimization and ATP sections.
8. Measure TX power from each of all 3 sectors of all 3 sectors of all 3 sectors 3. Disable BBX1, BBX8, and 6. Disable BBX-2, BBX-9, and 9. Disable BBX-3, BBX-7, and BBX6 BBX-4 BBX-5 Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP RMF-5...
4, and BBX 14.Measure TX power of C3-S3 and C4-S1. 17.Measure TX power C3-S1 and C4-S2. 15.Disable BBX-2, BBX-8, BBX-6, and BBX-10. 18.Disable BBX 3, BBX 9, BBX 4, and BBX RMF-6 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
– BBX-12 (C2-S6) – BBX-10 (C2-S4) 2. Measure TX power from each of all 6 sectors. 5. Measure TX power from each of all 6 sectors. 3. Disable BBXs. 6. Disable BBXs. Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP RMF-7...
8. This device must accept any interference received, including interference that may cause undesired operation. Part 15.21 – INFORMATION TO USER CAUTION Changes or modifications not expressly approved by Motorola could void your authority to operate the equipment. 15.105(b) – INFORMATION TO USER NOTE...
You should not attempt to repair this equipment yourself. This equipment contains no customer or user-serviceable parts. Changes or modifications not expressly approved by Motorola could void your authority to operate this equipment. 1X SC 4812T-MC Multicarrier BTS Optimization/ATP...
Motorola Lifecycles Customer web page at http://services.motorola.com, or contact your Motorola account representative. If Motorola changes the content of a manual after the original printing date, Motorola publishes a new version with the same part number but a different revision character. Text conventions The following special paragraphs are used in this manual to point out information that must be read.
Page 29
– the page number(s) with the error – a detailed description of the error and if possible the proposed solution Motorola appreciates feedback from the users of our manuals. Contact us Send questions and comments regarding user documentation to the email address below: cdma.documentation@motorola.com...
Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the equipment. Motorola, Inc. assumes no liability for the customer’s failure to comply with these requirements.
Page 31
Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification of equipment. Contact Motorola Warranty and Repair for service and repair to ensure that safety features are maintained. Dangerous procedure...
Manual Number – 68P64115A21 Manual Title 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Version Information The following table lists the manual version, date of version, and remarks on the version. Revision bars printed in page margins (as shown to the side) identify material which has changed from the previous release of this publication.
SC Product Family Frame Mounting Guide (which covers the physical “bolt down” of all SC series equipment frames) 1X SC 4812T-MC BTS Hardware Installation (which covers BTS specific cabling configurations for Packet Backhaul and the addition of carriers to the BTS) In most applications the same test procedure is used for all equipment variations.
CDMA operating frequency programming information, manual test setup information, procedures for verifying that the Voltage Standing Wave Ratio (VSWR) of all antennas and associated feed lines fall within acceptable limits, and procedures for downloading ROM and RAM code. Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP...
TX path continues and ends at the top of the RFDS TX directional coupler antenna feedline port installed in the ancillary equipment frame. The TX paths are identical for the starter and expansion frames. 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
Page 37
1–12, and is optimized to all antenna ports.) A single value is generated for each path, thereby eliminating the accumulation of error that would occur from individually measuring and summing the gain and loss of each element in the path. Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP...
Refer to Appendix C for a detailed FRU Optimization/ATP Test Matrix outlining the minimum tests that must be performed anytime a BTS RF subassembly or cable associated with an RF path is replaced. 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
This method requires accurate test cable characterization using shop test equipment. Characterized cables should be tagged with the characterization information, and the measured losses entered into the LMF before field optimization. Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP...
20X CD ROM drive 3 1/2 inch floppy drive 56kbps V.90 modem Serial port (COM 1) Parallel port (LPT 1) PCMCIA Ethernet interface card (for example, 3COM Etherlink III) with a 10Base–T–to–coax adapter 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
– Short pins 7 and 8 together, and short pins 1, 4, and 6 together on each connector. Figure 1-1: Null Modem Cable Detail 9–PIN D–FEMALE 9–PIN D–FEMALE ON BOTH CONNECTORS SHORT PINS 7, 8; RSD/DCD RSD/DCD SHORT PINS 1, 4, & 6 FW00362 Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP...
Required Test Equipment and Software 68P64115A21–B MMI Interface Kit Motorola cable part number CGDSMMICABLE219112 is used to connect the LMF to the BTS. Communications System Analyzer CDMA/analog Table 1-1: CDMA LMF Test Equipment Support Table Item Description Test Capability Test Sets...
Page 43
Fluke Model 8062A with Y8134 test lead kit or equivalent; used for precision dc and ac measurements, requiring 4–1/2 digits. Directional Coupler Narda Model 30445 30 dB (Motorola Part No. 58D09643T01 ) 800 MHz coupler terminated with two Narda Model 375BN–M loads, or equivalent.
Low Frequency Receiver/High Stability Oscillator (LFR/HSO) frequency verification. Itasca Alarms Test Box Itasca CGDSCMIS00014 – This test box may be used as a tool to assist in the testing of customer alarms. 1-12 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
Compact Flash. Type of flash memory card used in the BTS router to store the Internetworking Operating System and configuration files. Concentration Highway Interface . . . continued on next page 1-14 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
Page 47
Link Access Protocol “D” Low Frequency Receiver Local Maintenance Facility LORAN LOng RAnge Navigational Multi–Channel CDMA MCIO Multicarrier Combiner Input/Output Multicarrier Module MGLI Master Group Line Interface . . . continued on next page Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP 1-15...
Page 48
QPSK Quadrature Phase Shift Keyed R15.x Motorola Software Release 2.15.0.39.10 or later. The version of the software which must be installed on BSS equipment to allow upgrading to Software Release 2.16.0.x. R16.0 Motorola Software Release 2.16.0.x. The version of the software which must be loaded on BSS equipment to upgrade it to software release 2.16.1.x.
Page 49
Serial Network Interface STRAU SC 9600 Transcoder/Rate Adaption Unit Traffic Channel Time Slot Interchanger TX Filter Transmit filter Universal Time Coordinates VWIC Voice Wide Area Network Interface Card WAN Interface Card (also VWIC) Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP 1-17...
BTS number, are also identified with unique Device ID numbers dependent upon the Frame ID number in which they are located. Refer to Table 1-3 and Table 1-4 for specific C–CCP Shelf Device ID numbers. 1-18 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
PA Breakers Power Supply Modules Power Amplifier Cage Enhanced Trunking Power Module Alarms Card TX Filter or TX Filter Terminators For clarity, doors are not shown. Multicarrier module (MCM) detail ti-CDMA-WP-00320-v01-ildoc-ftw 1-20 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
PA Breakers Power Supply Modules Power Amplifier Cage Power Alarms Enhanced Card Trunking Module TX Filter or TX Filter Terminators Multicarrier module For clarity, doors are not shown. (MCM) detail ti-CDMA-WP-00318-v01-ildoc-ftw 1-22 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
BTSs. Functionally however, and for the purpose of Optimization and ATP, those frames are identical. Power Enhanced Amplifier Trunking Module Cage TX Filter Power Amplifier Cage ti-CDMA-WP-00210-v01-ildoc-ftw REF 1-24 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
The upper portion of the frame which houses circuit breakers, cooling fans, and the C–CCP shelf. The lower portion of the frame which houses the power amplifiers and PA fans, Parallel Linear Amplifier Combiner, enhanced trunking module(s) and TX filters. Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP 1-25...
TX antenna Alarm connections Power input LAN connections GPS input or Remote Global Positioning System (RGPS) on the Site I/O Board Remote Global Positioning System Distribution (RGD) Expansion frame connection Ground connections 1-26 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
ON CONFIGURATION) FRONT EXP IN FILLER RF EXPANSION PORT TO ANOTHER ETHERNET ROUTER (IF USED; OTHERWISE, FILLER PLATE) PLATE BTS (USED ONLY IF EXPANSION FRAME INSTALLED; OTHERWISE, FILLER PLATE INSTALLED) ti-CDMA-WP-00188-v02-ildoc-ftw Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP 1-27...
GLI2s or GLI3s. ti-CDMA-WP-00037-v01-ildoc-ftw REF NOTE The 4th carrier (BBX10–12) is not supported in a converted SC 4812T MC BTS at this time. An upcoming feature release will address 4th carrier support. Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP 1-29...
Optimization and ATP, those frames are identical. – The 4th carrier (BBX10–12) is not supported in a converted SC 4812T MC BTS at this time. An upcoming feature release will address 4th carrier support. 1-30 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
Each type has unique characteristics and must be optimized accordingly. For more information on the differences in site types, please refer to the 1X SC 4812T-MC BTS Hardware Installation manual. CDF/NECF The Configuration Data File (CDF) or Network Element Configuration File (NECF) contains site type and equipage data information and passes it directly to the LMF during optimization.
Always wear a conductive, high impedance wrist strap while handling the any circuit card/module to prevent damage by ESD. Cabling Inspection Using the site-specific documentation generated by Motorola Systems Engineering, verify that the following cable systems are properly connected: Receive RF cabling – up to 12 RX cables Transmit RF cabling –...
If the multimeter stays at 0 Ω after inserting any board/module, a short probably exists in that board/module. Replace the suspect board/module and repeat the test. If test still fails, isolate the problem before proceeding..continued on next page 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
Page 71
Repeat Step 3 (for –48 V) or Step 4 (for +27 V) after seating each LPA and associated LPA fan module. A typical response is that the ohmmeter will steadily climb in resistance as capacitors charge, stopping at approximately 500 Ω Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP...
Pre–Power–up Tests 68P64115A21–B Figure 2-3: Breaker Panel – 27 V shown (–48 V is Similar) TOP OF FRAME DC FILTER 1 DC FILTER 2 INPUT FILLER CONNECTOR/ PLATE DC FILTER ti-CDMA-WP-00224-v01-ildoc-ftw 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
The negative power cable is red or blue. The positive power cable (ground) is black. Motorola recommends that the DC input power cable used to connect the frame to the main DC power source conforms to the guidelines outlined in Table 2-3.
Page 74
On –48 V BTS: –48 Vdc nominal On +27 V BTS: +27 Vdc nominal On –48 V BTS: Plug in PSMs one at a time and verify ’Green’ LEDs on PSMs light. 2-10 1X SC 4812T-MC Multicarrier BTS Optimization/ATP Sept 2003...
Page 75
On –48 V BTS: –48 Vdc nominal On +27 V BTS: +27 Vdc nominal Repeat Steps 1 through 8 for additional co–located frames (if equipped). Sept 2003 1X SC 4812T-MC Multicarrier BTS Optimization/ATP 2-11...