CAUTION: The PIDU Plus is not waterproof and should be mounted away from sources of
moisture. If mounted outdoors, the unit should be mounted in a rain proof enclosure, preferably
ventilated.
It is also recommended that you fit a drip loop on the PIDU Plus to ODU cable to ensure that
any moisture that runs down the cable into the cabinet or enclosure cannot enter the PIDU Plus.
As shown in
Figure
24. The network connection and mains cable should be treated in the same
way if there is a risk that they can carry moisture to the PIDU Plus.
Figure 24 PTP 500 Series PIDU Plus Drip Loop Configuration
CAUTION: It is possible for moisture to enter the cable due to damage to the outer protective
layer. This moisture can track down the inside of the cable, filling up the drip loop and eventually
finding its way into the PIDU Plus. To protect against this the outer protective layer of the cable
can be opened up at the bottom of the drip loop to allow this moisture to escape.

7.7.10 Powering Up

The PTP 500 Series Bridge is supplied as a pair of matched Master/Slave units. The Master unit
can now be powered up and accessed using the default URL http://169.254.1.2/; the Slave unit
can be accessed using http://169.254.1.1/.
Prior to powering up the PTP 500 Series Bridge, a computer with web browsing capabilities should
be configured with an IP address of 169.254.n.n and subnet mask of 255.255.0.0 where n is any
value between 1 and 254 but excluding 1.1 or 1.2. If the default addresses of the unit 169.254.1.1/2
clashes with an address you are already using on your LAN, or you are not sure, you should set up
an isolated LAN. As the LAN connection presented at the PIDU Plus has a default configuration