Emc Immunity Compliance; Radio Certifications; Radio Certifications - 5.4 Ghz Variant - Motorola MOTOWI 4 User Manual

Point-to-point wireless solutions
Table of Contents

Advertisement

17.4 EMC Immunity Compliance

Top-level Specification ETSI 301-489.
Specification
EN 55082-1 Generic EMC and EMI
requirements for Europe
EN 61000-4-2: 1995 Electro Static Discharge
(ESD), Class 2, 8 kV air, 4 kV contact
discharge
EN 61000-4-3: 1995 ENV50140: 1993
(radiated immunity) 3 V/m
EN 61000-4-4: 1995 (Bursts/Transients),
Class 4, 4 kV level (power lines AC & DC)
EN 6100045:1995, (Surge Immunity)
EN 61000-4-6: 1996 (Injected RF), power
line, Class 3 @ 10 V/m
17.5 Radio Certifications
17.5.1 Radio Certifications - 5.4 GHz Variant
Specifications
Region Specification
USA
FCC Part 15 Class B
Canada
CSA Std C108.8, 1993 Class B
Europe
EN55022 CISPR 22
Region Specification (Type Approvals)
USA
FCC Part 15.407
EU
EN301 893 V1.2.3/V1.3.1
Canada
RSS 210 Issue 7
191
Comment
Testing will be carried to ensure immunity to
15kV air and 8kV contact
Signal lines @ 0.5 kV open circuit voltage
Requires screened connection to users network
Signal lines, Class 3 @ 3 V RMS
unmodulated.