Multibeam Models
These models are suitable for whole body
detection and must not be used to detect arms
or legs.
The
minimum
safety
according to the following formula:
The recommend height H from the reference surface G
(ground) is as follows (ISO 13855 Standard) :
EOS2 2B
EOS2 3B
EOS2 4B
Horizontal positioning of the light curtain
When the direction of approach of the body is parallel to
the plane of the protected area, the light curtain must be
positioned so that the distance between the far end of the
dangerous area and the outermost beam is equal to or
greater than the minimum safety distance S calculated as
follows:
S = 1600(t
where H is the height of the protected surface from
the machine reference plane;
In this case, H must always be less than of 1m
(ISO 13855 Standard).
14
distance
S
is
S = 1600 (t
+ t
) + 850
1
2
MODEL
BEAMS
2
3
4
Table 3 - Height H of Multibeam models
+ t
) + 1200 – 0.4H
1
2
H = 15(D-50)
(D=resolution)
Light grid
determined
direction
of
approach
reference plane
Recommended height H (mm)
400 – 900
300 – 700 – 1100
300 – 600 – 900 - 1200
direction
of approach
Light curtain
reference plane
Figure 15 - Horizontal positioning
8540738 • 2nd December 2009 • Rev.2
EOS2 SAFETY LIGHT CURTAIN
point of
danger
Figure 14 - Multibeam
point of
danger
G
G