Reer JANUS Installation, Use And Maintenance Manual

Reer JANUS Installation, Use And Maintenance Manual

Type 4 safety light curtain
Hide thumbs Also See for JANUS:
Table of Contents

Advertisement

TYPE 4 SAFETY LIGHT CURTAIN
I
N
S
T
A
L
L
I
N
S
T
A
L
L
I
N
S
T
A
L
L
I
N
S
T
A
L
L
I
N
S
T
A
L
L
A
T
I
O
I
N
S
T
A
L
L
A
T
I
O
I
N
S
T
A
L
L
A
T
I
N
S
T
A
L
L
A
T
I
N
S
T
A
L
A
I
N
S
T
A
L
A
JANUS
A
Z
I
O
N
E
,
U
S
O
A
Z
I
O
N
E
,
U
S
O
A
T
I
O
N
,
U
S
E
A
T
I
O
N
,
U
S
E
N
,
U
T
I
L
I
S
A
T
N
,
U
T
I
L
I
S
A
T
I
O
N
,
B
E
D
I
E
N
I
O
N
,
B
E
D
I
E
N
C
I
Ó
N
,
U
S
O
C
I
Ó
N
,
U
S
O
www.reer.it
E
M
A
N
U
T
E
E
M
A
N
U
T
E
A
N
D
M
A
I
N
T
E
A
N
D
M
A
I
N
T
E
I
O
N
E
T
M
A
I
I
O
N
E
T
M
A
I
U
N
G
U
N
D
W
U
N
G
U
N
D
W
Y
M
A
N
T
E
N
I
M
Y
M
A
N
T
E
N
I
M
N
Z
I
O
N
E
N
Z
I
O
N
E
N
A
N
C
E
N
A
N
C
E
N
T
E
N
A
N
C
E
N
T
E
N
A
N
C
E
A
R
T
U
N
G
A
R
T
U
N
G
I
E
N
T
O
I
E
N
T
O

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JANUS and is the answer not in the manual?

Questions and answers

Summary of Contents for Reer JANUS

  • Page 1 TYPE 4 SAFETY LIGHT CURTAIN JANUS Ó Ó www.reer.it...
  • Page 2: Table Of Contents

    LIGHT CURTAIN ............................4 MUTING FUNCTION ............................. 5 SERIES "ML" - PREASSEMBLED KIT OF JANUS LIGHT CURTAIN AND SENSOR ELEMENT “Ml S” Integrated Muting sensors – only for one-way openings with pallet exit......... 5 SERIES "MT" - KIT PREASSEMBLED OF JANUS LIGHT CURTAIN AND SENSORS ELEMENTS “MT SI”...
  • Page 3 DIMENSIONS ..............................34 JANUS "MI" - "J" ............................34 JANUS "ML" ..............................35 JANUS "MT" ..............................35 JANUS "ML S2" - "MT S4" ........................... 36 TECHNICAL DATA ............................37 CHECKOUTS AND MAINTENANCE ......................41 TROUBLESHOOTING ..........................42 ACCESSORIES ............................44 GUARANTEE ..............................
  • Page 4: Introduction

    This symbol indicates an important personal safety warning. Failure to comply with the warning may result in very high risks for exposed personnel. The JANUS safety light curtain is a multi-beam opto-electronic safety system of the Type 4 category of electro-sensitive devices (in accordance with IEC 61496-1,2; EN 61496-1) – if necessary equipped with MUTING function (“M”...
  • Page 5: Principle Of Operation

     90mm (protected heights from 300mm to 1800mm) ("MI" models): PROTECTION OF THE LIMBS. JANUS is also available in a Multibeam version ("MI", "MT" and "ML" models) with a pitch between the lenses of:  500mm (2 beams), 400mm (3 beams), 300mm (4 beams only models "MI"), "MILR"...
  • Page 6: Muting Function

    Muting sensors. The JANUS system is available in the “ML" and "MT” models (with 2 integrated opto-electronic sensors) and "MI" models to which 2 or 4 sensors of various type can be connected (proximity, optical, capacitive etc).
  • Page 7: Series "Mt" - Kit Preassembled Of Janus Light Curtain And Sensors Elements "Mt Si" And "Mt Se" Integrated Muting Sensors - For Two-Way Openings With Pallet Entrance/Exit

    (timeout) can be set to 30 seconds or 90 Figure 3 minutes. SERIES "MT S4" - KIT PREASSEMBLED OF JANUS LIGHT CURTAIN AND SENSORS ELEMENTS “MT S” Integrated Muting sensors – for two-way openings with pallet entrance/exit. This model is two-way and is useful for protecting pallet entrance/exit openings (Figure 4).
  • Page 8: Series "Ml S2" - Kit Preassembled Of Janus Light Curtain And Sensors Elements "Ml S" Integrated Muting Sensors - For One-Way Openings With Pallet Exit

    SERIES "ML S2" - KIT PREASSEMBLED OF JANUS LIGHT CURTAIN AND SENSORS ELEMENTS “ML S” Integrated Muting sensors – for one-way openings with pallet exit. In this model, the sensors 1 and 2 are on the same side of the vertical light curtain and are placed in front of the guarded opening (Figure 5).
  • Page 9 CONNECTION WITH 4 EXTERNAL SENSORS Using 4 sensors, two methods of operation are possible: Sequential (figure 7) The Muting function is activated following sequential interruption of Receiver sensors S1 and S2 and of sensors S3 and S4. It is important to remember that, for correct actuation of the Muting function, Emitter the sequence indicated in Figure 8 and Table 1 is required...
  • Page 10: Mi Models Used With "L" Operational Logic

    Sensor 1 Figure 10 - Parallel sensors Figure 9 - Crossed sensors INSTALLATION Before installing the JANUS safety system, check that:  The safety system is used only as stopping device and not as machine control device.  The machine can be controlled electrically.
  • Page 11  If JANUS light curtains are used with palletizers, depalletizers and stacking/destacking machines for empty pallets, refer to European standard EN 415-4. 8540573 • 16/09/2016 • Rev.20...
  • Page 12: Positioning

    POSITIONING Protection of the guarded opening by JANUS must be integrated with suitable mechanical guards. While the "MI" model permits various types of installation (2, 4 sensors, one- or two-way), the "ML" and "MT" have been designed for "dedicated" use.
  • Page 13 to avoid the possibility of accidental passing through the light curtain with Muting active (Figure 12). Dimension to be reduced to a minimum Material Mechanical guards Figure 12 4 sensors For correct positioning of sensors 1, 2, 3 and 4, i.e. those that manage enabling and disabling of the Muting function, take into account the following: SEQUENTIAL (Figure 8, Figure 13 Table 1): ...
  • Page 14: Positioning And Adjustment Of Sensor Elements For "Ml" And "Mt" Series

    POSITIONING AND ADJUSTMENT OF SENSOR ELEMENTS FOR "ML" AND "MT" SERIES: As already mentioned, the pre-assembled JANUS "ML" and "MT" kit consist of a vertical light curtain and of one ("ML" series) or two ("MT" series) horizontal sensor element in which the Muting sensors are integrated.
  • Page 15: Calculation Of The Safety Distance

    CALCULATION OF THE SAFETY DISTANCE The light curtain must be positioned at a distance exceeding or equal to the minimum safety distance S so that a dangerous point can be reached only after stopping the dangerous action of the machine (Figure 16). Referring to European standard EN999, the minimum safety distance S must be calculated according to the following formula: S = K (t...
  • Page 16: Vertical Positioning Of The Light Curtain

    VERTICAL POSITIONING OF THE LIGHT CURTAIN Models with resolution 30, 40mm. Light  These models are suitable for detecting the hands Dangerous curtain point The minimum safety distance S is calculated according to the following formula: S = 2000 (t ) + 8(D-14) Direction (D=resolution)
  • Page 17 Dimensions in m From low level (floor) Above the conveyor (roller bed) Device with minimum 3 beams Device with minimum 2 beams Figure 20 Protection of the opening with JANUS light curtain and mechanical side guards. 8540573 • 16/09/2016 • Rev.20...
  • Page 18: Multiple Systems

    MULTIPLE SYSTEMS When several JANUS systems are used, these must not interfere optically with each other. Position the elements so that the beam emitted by the Emitter of a system is received only by the respective Receiver. Figure 21 provides various examples of correct positioning of two photo-electric systems.
  • Page 19 JANUS JANUS Long Range SENSITIVE AREA EMITTER RECEIVER Figure 23 After installation, check for any reflective surfaces, intercepting the beams first of all at the center and those close to the Emitter and Receiver. During this procedure, the red led on the Receiver must never switch off.
  • Page 20: Light Signals

    Table 3 If a fault is detected, the led will indicate the type of alarm (ref. "TROUBLESHOOTING"). * The value of the selected range depends on the JANUS model. (Refer TECHNICAL DATA - page 31). 8540573 • 16/09/2016 • Rev.20...
  • Page 21: Receiver Signals

    This check is also indispensable in all cases of malfunctioning (ref. "TROUBLESHOOTING"). During display of the configuration, the display will show the letter "C" while during normal functioning, a hyphen "-" will be displayed. Initial display (JANUS “M”) (JANUS “J”) Figure 25 INITIAL CONFIGURATION...
  • Page 22 Normal display Figure 26 NORMAL FUNCTIONING COLOR (LED ON) (LED OFF) YELLOW Interruption Sensor 1 Sensor 1 clear YELLOW Interruption Sensor 2 Sensor 2 clear YELLOW Interruption Sensor 3 Sensor 3 clear YELLOW Interruption Sensor 4 Sensor 4 clear YELLOW Muting active Light curtain active ORANGE...
  • Page 23: Electrical Connections And Connectors

    ELECTRICAL CONNECTIONS AND CONNECTORS Caution Before making the electrical connections, always check that the voltage available matches that indicated in the technical data.  The Emitter and Receiver must be powered at 24V dc ±20%.  The external power supply must comply with EN 60204. The electrical connections must be made according to the diagrams provided in this manual.
  • Page 24: Receiver Connections (Main Connector - Male)

    RECEIVER CONNECTIONS (Main Connector - Male)  Make sure the M23 connector is screwed down tightly to ensure correct barrier operation! (4 turns) COLOR NAME TYPE DESCRIPTION FUNCTIONING 24VDC with Muting White MUT. LAMP Muting lamp output active 24VDC with : OSSD2 ...
  • Page 25: Connections Connector M12 N. 1 (For Muting Sensor) ("Mi" Models) (Female Connector)

    CONNECTIONS CONNECTOR M12 n. 1 (FOR MUTING SENSOR) ("MI" MODELS) (Female Connector) COLOR NAME TYPE DESCRIPTION FUNCTIONING Brown 24 VDC Power supply sensors 1 and 3 Positive < 5VDC : SENSOR FREE White SENSOR 1 Input SENSOR 1 11÷30 VDC : SENSOR ACTUATED Blue 0 VDC Power supply sensors 1 and 3...
  • Page 26: Receiver Connections J Lr M12 Models

    INPUT Feedback external contactors SELECTION OF CONFIGURATION AND OPERATING MODE The inputs of the JANUS light curtain receiver make it possible to configure various operating modes. At power-on, for correct functioning, the various inputs must be connected as indicated below.
  • Page 27: Selection Of Manual/Automatic Functioning

    It must not be possible to reach the control from inside the danger area. SELECTION OF MANUAL/AUTOMATIC FUNCTIONING CONNECTIONS AUTOMATIC JANUS RECEIVER MANUAL JANUS RECEIVER PIN 13 PIN 14...
  • Page 28: Selection Of The Maximum Duration And Type Of Muting

    SELECTION OF THE MAXIMUM DURATION AND TYPE OF MUTING The inputs of the JANUS light curtain receiver make it possible to configure the various types of Muting available and the maximum duration of the Muting condition (timeout). At power-on, for correct functioning, the various inputs must be connected as indicated below.
  • Page 29: Muting Override Function ("M" Models)

    MUTING OVERRIDE FUNCTION (“M” MODELS) The OVERRIDE function must be used when the machine stops due to incorrect Muting activation sequences with the material obstructing the guarded opening. In this situation, the OSSD outputs are not active as the light curtain and/or at least one Muting sensor is occupied.
  • Page 30: System Status" Output ("M" Models)

    The minimum duration of the TEST function must be 40 msec. SAFETY MODULES MJB1 - MJB2 - MJB3 - MJB4 JANUS light curtain can be integrated by the safety modules MJB1 - MJB2 - MJB3 and MJB4. In fact they contain terminal boards, pre-wired connection, dip switches for the configuration choice and two safety relays connected to the light curtain outputs.
  • Page 31: Example Of Connection With External Contactors K1/K2 With Start/Restart Interlock Activated

    4 of the Emitter according to table 6 (page 20) and to the "TEST FUNCTION" paragraph of page 26. For correct operation (in the case of JANUS "M" without the use of Muting) the muting light must be connected (pin 1) and the Muting mode must be configured correctly (pin 7-8-9-10) following the indications in Table 13.
  • Page 32: Example Of Connection With Ad Sr0 With Start/Restart Interlock Activated

     JANUS is equipped with an output (pin 1 of connector M23 on the receiver) to which the indicator light can be connected and is able to monitor correct functioning of this and also that it is present.
  • Page 33: Configuration And Operation Modes J Lr M12

    CONFIGURATION AND OPERATION MODES J LR M12 The JANUS J LR M12 operation mode is selected realizing appropriate connections on the M12 8 poles of the active element (Table 15 and Table 16). AUTOMATICO MODE In this operation mode the OSSD1 and OSSD2 safety outputs follow the barrier status : ...
  • Page 34: Manual Mode

    MANUAL MODE In this operating mode the safety outputs OSSD1 and OSSD2 are activated (+24VDC) only if the protected area is free and after the reception of the RESTART signal, using a push button or thank to an appropriate control on the SEL_A or SEL_B input (ref.Table ). After an interception of the protected area, the safety outputs will be de-activated.
  • Page 35: Dimensions

    DIMENSIONS The following tables shows the dimensions of the different JANUS models; refer to the drawings of pages 34 ÷ 36. "J" MODELS 16m RANGE DIMENSION 1200 A (TX - RX) 1036 1136 1036 1336 1036 1136 1210 (Protected Area) (First beam position) "MI"...
  • Page 36: Janus "Ml

    JANUS "ML" Dimension Figure 33 JANUS "MT" Dimension Figure 34 8540573 • 16/09/2016 • Rev.20...
  • Page 37: Janus "Ml S2" - "Mt S4

    JANUS "ML S2" - "MT S4" (Present on MT S4 models only) Dimension ML S2 / MT S4 Figure 35 Figure 37 - Fastening inserts FI Figure 36 - Fastening brackets LL 8540573 • 16/09/2016 • Rev.20...
  • Page 38: Technical Data

    TECHNICAL DATA GENERAL DATA Safety category  30 Response time Reset automatic or manual selectable 24  20% Power supply M12 – 5 pins (male) Emitter M12 – 8 pins (male) Receiver Connections M23 – 19 pins (male) Receiver * Muting sensors M12 – 5 pins (female) Protection rating IP 65 Max.
  • Page 39 2 opto-electronic - integrated – pre-aligned– prewired Muting sensors Muting sensor detection plane adjustable height and slope MT SERIES PRE-ASSEMBLED KIT OF JANUS LIGHT CURTAIN AND SENSOR ELEMENTS “MT SI” AND “MT SE” 2 – 3 Number of beams 1 ÷ 2,5 Operating range 0 ÷...
  • Page 40 MI - MILR SERIES Number of beams of light curtains for 2 – 3 – 4 detection of body in access control Operating range Low / High 8 ÷ 30 / 18 ÷ 60 Muting system Two-way with 2 or 4 sensors with max. concurrent actuation time 4 sec Two-way sequential with 4 sensors Muting Sensors external with relay or PNP output...
  • Page 41 JLR SERIES Resolution 40 mm 1204 Number of beams Response time 28,5 Overall barrier ht. 1036 1336 1,02E-08 1,17E-08 1,32E-08 PFHd * 98,37% 98,49% 98,57% DCavg MTTFd years JLR SERIES Number of beams of light curtains 2 – 3 – 4 for detection of body in access control Operating range Low / High 8 ÷...
  • Page 42: Checkouts And Maintenance

    If the ORANGE weak signal LED on the Receiver switches on (LED 1 in Figure 26), check that: the front surfaces are clean; the Emitter and Receiver are aligned correctly. If the LED stays on, contact the REER service department. 8540573 • 16/09/2016 • Rev.20...
  • Page 43: Troubleshooting

    Barrier configured for 2 sensors but found 3 Verify the number of the sensors connected and or 4 sensors (the corrispondent led flashes) the selected configuration Send the equipment for repair to the REER Internal error laboratories. Send the equipment for repair to the REER Internal error laboratories.
  • Page 44 CODE DIAGNOSIS REMEDY (Not flashing) Short-circuit between the OSSD outputs Carefully check the connection of terminals 2 and 3. Carefully check the connection of terminals 2 and 3 Overload of the OSSD outputs (OSSD) on the connector. If necessary, adjust load reducing the current required to max 500 mA (2.2 F) Carefully locate the interfering Emitter and take action in one of the following ways:...
  • Page 45: Accessories

    M12 female connector 5 poles 15 m cable 1330952 CD20 M12 female connector 5 poles 20 m cable 1330957 CABLES WITH 2 CONNECTORS FOR JANUS REICEIVERS AND MUTING BOX MJB 1 CONNECTION / MJB2 CJBR3 3 m cable with 2 M23 female connectors 1360970 CJBR5...
  • Page 46: Guarantee

    GUARANTEE All new JANUS systems are guaranteed by REER for a period of 12 (twelve) months under normal working conditions, against defects due to faulty materials and workmanship. During the aforesaid period, REER promises to replace faulty parts free of charge. This guarantee covers both material and labour.
  • Page 47 REER SpA via Carcano 32 10153 – Torino Italy dichiara che le barriere fotoelettriche JANUS sono Dispositivi Elettrosensibili di Sicurezza (ESPE) di :  Tipo 4 (secondo la Norma EN 61496-1:2013; EN 61496-2:2013)  SIL 3 (secondo la Norma EN 61508-1:2010; EN 61508-2:2010; EN 61508-3:2010; EN 61508-4:2010) ...
  • Page 48 REER S.p.A. 32 via Carcano 10153 Torino Italia Tel. +39/0112482215 r.a. Fax +39/011859867 Internet: www.reer.it e-mail: info@reer.it...

Table of Contents

Save PDF