Step 2: Click the "Next>" button to start the installation.
Step 3: Check your DAQ Card is or not on supported list, then click the "Next>" button.
Step 4: Select the installed folder, the default path is C:\ICPDAS\UniDAQ, confirm and click the
"Next>" button.
Step 5: Check your DAQ Card on list, then click the "Next>" button.
Step 6: Click the "Next>" button on the Select Additional Tasks window.
Step 7: Click the "Next>" button on the Download Information window.
Step 8: Select "No, I will restart my computer later" and then click the "Finish" button.
For detailed information about the driver installation, please refer to Chapter 2.1 "Getting the
UniDAQ Driver DLL Installer package" of the UniDAQ SDK user manual.
Jumper Setting
Please make sure JP1 and JP2 jumper is kept in default setting before self-test, as follows:
(
This example uses this power supply.)
1. CON1: The Connector for DI <0...15> and DO<0...15>. Refer to Section 6 Pin Assignments.
2. CON2: The Connector for DI <16...31> and DO<16...31>. Refer to Section 6 Pin Assignments.
3. SW1: DIP Switch used to configure the Board ID. Refer to PISO-P32x32/x64 Series User
Manual.
4. JP1: Used to set the Internal or External Power for DI <0...15> on CON1, as above table.
5. JP2: Used to set the Internal or External Power for DI <16...32> on CON2, as above table.
2
PEX-P32A32/PISO-P32A32U Series Quick Start Guide
WebSite: http:// www.icpdas.com.tw
Jumper
E-Mail: service@icpdas.com , service.icpdas@gmail.com
JP1/JP2
ICP DAS CO., LTD.
Internal Power
External Power
(Default Setting)