Electrical Specifications

HAWK MV-4000-03, -03C, -13, -13C, -20, -20C, -50, -50C
Operating voltage for the HAWK MV-4000 under testing conditions
Rated current
Operating voltage tolerance
I/O Specifications
Optoisolated Output Signals
Optoisolated Input Signals
0-10 V Analog Control Output Signal
Varioptic Caspian C-39N0-160-I2C or C-39N0-250-I2C Liquid Lens
Typical
a. The PTC is an automatically resetting fuse.
b. This occurred under the following condition: output pulled to 24 V using 1 kW.
c. Regardless of whether the signal is sinking or sourcing, this measurement is the same.
d. Maximum input current at max. ON voltage. The connected device must not limit the current to a value
lower than this.
e. Minimum input current at min. ON voltage. Can be used to calculate bleeding resistor needed for 2-wire
proximity sensor.
f. Recommended > 12 V when using HAWK MV-4000 breakout board.
HAWK MV-4000 Smart Camera Guide
HAWK MV-4000 General Specifications
Operating Voltage
Sink Current
Maximum Leakage Current
ON Voltage
a
PTC
Fuse Max. Time-to-Trip
OFF-to-ON Response
ON-to-OFF Response
Operating Voltage
Input Current (Sink or Source)
ON Voltage Level
OFF Voltage Level
OFF-to-ON Response
ON-to-OFF Response
Non-isolated. Note that the 0-10 V is intended for reference voltage only (< 1 mA).
Supplied Voltage
Rated Current
24 V
600 mA
± 10%
24 V (26 V abs. max.)
50 mA max.
1 mA@ 24 V
1 mA@ 26 V
0.4 V @ 2 mA
1.1 V @ 25 mA
1.5V @ 50 mA
1 sec @ 0.5 A
b
2 ms to reach 4 V
c
50 ms to reach 11 V
24 V (26 V abs. max.)
d
e
3.5 mA max.
, 1 mA min.
f
> 11 V
< 4 V
6 ms
80 ms
5 V
50 mA
C
C-5