Pic Test Error Codes; Pic Test Section 1 - HP Series 37 Reference Manual

3000 series self test and maintenance mode
Table of Contents

Advertisement

Error Codes
PIC TEST ERROR CODES
The Slot Test wili display one of the following error codes if the PIC test fails. The Tests are run in the
same sequence as the test sections and the test stops on the first failure found.
PIC Test Section 1
Initialization test, Initialize the PIC and then check that the registers contain expected data.
Code
Error
0104
Register 4 initialization error (expected $0000)
0105
Register 5 initialization error (expected $0000)
0106
Register 6 initialization error (expected $0020)
0107
Register 7 initialization error (expected $0000)
0108
Register 8 initialization error (expected $0000)
010A
Register A initialization error (expected $0000)
010F
Register F initialization error (expected $0087+(8*channel#))
PIC Test Section 2
Bo.sic operations, test OBII, IPOLL, SMSK
&
RMSK.
Code
Error
0201
SMSK/RMSK test, PIC did not respond with mask bit set
0202
SMSK/RMSK test, PIC did not respond with mask bit cleared
0203
PIC did not set IRQ after SMSK on selected channel
0204
Improper IPOLl response after SMSK (no response,
wrong response, or multiple channels responding)
0205
Improper OBII data from this channel after SMSK
0206
Improper Register D response after SMSK
0207
Improper IPOll response (should have been clear)
0208
Recieved no CSRQ after issuing a SlOP
0209
Wrong channel is responding to SPOll
020A
Improper OBSI data after SPOll
020B
~
Improper Register F data after SPOll
020C
Improper CSRQ response after HIOP (should have been Zero)
0200
Improper SPOll after HIOP (should have been Zero)
020E
Improper OBSI response to SPOll after HIOP
(should have
point,~J
to device 7)
NOV 84
A-4