HP Series 37 Reference Manual page 91

3000 series self test and maintenance mode
Table of Contents

Advertisement

Operating Instructions
16) TICDIAG prompts for the SIB tests to run.
If
the console is on the TIC under test, no SIB test can
be run. Enter the tests by name or specify
ALL
or
NONE.
ENTER SIB TESTS TO BE RUN: (DEFAULT
THE LAST SET OF TESTS RUN, IF ANY)
The possible test names are:
1MB-SIB COMMUNICATIONS (1M)
INITIAL REGISTER VALUES (IN)
ERROR CIRCUITRY (E)
RESET/INIT (RES)
IRQ LOGIC (IR)
MEMORY (M)
SEQUENCING (SE)
TIMEOUT (TIM)
BOARD ENABLE (BO)
PORT POINTER (P)
FREEZE (FR)
TIC BUS BUFFERS (TIC)
DIRECT COMMAND (DI)
FIFO (FI)
STATE COUNTER (ST)
DMA ADDRESS COUNTER (DM)
COMP/CTR LOOPBACK (C)
READ 1MB (REA)
WRITE 1MB (W)
BEGIN FLAG/LEFT-RIGHT FLAG (BE)
ALL (AL)
NONE (N)
[RETURNl
The test names can
be
abbreviated as indicated. You can enter a list of tests, separated by
semicolons.
ALL
indicates that all available SIB tests are to be run.
NONE
indicates that testing of
the SIB will not
be
done. If you press Carriage Return, the last SIB tests specified
(if
anyl will be
retained.
ALL
is the recommended response when using the diagnostic in the field.
SEP 84
2-4

Advertisement

Table of Contents
loading

Table of Contents