Set Pvc Cdvt - Avaya Cajun P550R Cli Reference Manual

Multiservice switch atm uplink
Hide thumbs Also See for Cajun P550R:
Table of Contents

Advertisement

set pvc cdvt

Command Mode
Description
Syntax
Sample Output
Avaya P550R/P580/P880/P882 Multiservice Switch ATM Uplink CLI Reference Guide, Version 2.0
Configure
Sets the Cell Delay Variation Tolerance for the specified pvc.
set pvc <pvcID> cdvt <cdvt-value>
Table 1-41. Arguments, Parameters, Keywords
Name
pvcID
cdvt - value
The following example sets the cdvt to 5.
ATM(configure)# set pvc 1-4-101 cdvt 5
CCDVT 5 set successfully for PVC 1-4-101
Avaya ATM Uplink Module CLI Commands
Definition
The identifier of the pvc. This is equal to
<physPort> - <vpi> - <vci>
(e.g., port number 1 with a vpi of 4 and a vci of
101 would have a pvcID of 1-4-101)
The Cell Division Variation Tolerance of the
pcv. Range is 1 - 10000.
1-71