set lec (max-time)

Command Mode
Description
Syntax
Sample Output
Avaya P550R/P580/P880/P882 Multiservice Switch ATM Uplink CLI Reference Guide, Version 2.0
Configuration
Set the unknown frame time interval for a LEC. Refer to the max-
count parameter for additional information.
* Note: You must disable a LEC each time you make a change to
the configuration. After you make configuration
changes, you must enable the LEC in order for the
changes to take effect.
set lec <lecID> max-time <max-time-value>
Table 1-30. Parameters, Keywords, Arguments
Name
lecID
max-time-value
This example sets the unknown frame time interval for LEC 2 to 45
seconds.
ATM(configure)# set lec 2 disable
LEC 2 has been disabled
ATM(configure)# set lec 2 max-time 45
Maximum Unknown Frame Time 45 has been set for
LEC 2
ATM(configure)# set lec 2 enable
LEC 2 has been enabled
Avaya ATM Uplink Module CLI Commands
Definition
The LEC identifier. The range of values is:
Minimum = 1, Maximum = 128.
The maximum unknown frame time,
measured in seconds. The range of values is:
Minimum = 1 second, Maximum = 60 seconds.
The default is 1.
1-39