Download Print this page
SEA GATE 1 DG R2BF Owner's Manual

SEA GATE 1 DG R2BF Owner's Manual

Control unit for sliding gates with inverter module
Hide thumbs Also See for GATE 1 DG R2BF:

Advertisement

Quick Links

®
Sistemi Elettronici
di Apertura Porte e Cancelli
English
International registered trademark n. 804888
GATE 1 DG R2BF
With inverter module
CONTROL UNIT FOR SLIDING GATES
(Cod. 23001235)
67411665
Rev.05 - 06/2016

Advertisement

loading
Need help?

Need help?

Do you have a question about the GATE 1 DG R2BF and is the answer not in the manual?

Questions and answers

Summary of Contents for SEA GATE 1 DG R2BF

  • Page 1 ® Sistemi Elettronici di Apertura Porte e Cancelli English International registered trademark n. 804888 GATE 1 DG R2BF With inverter module CONTROL UNIT FOR SLIDING GATES (Cod. 23001235) 67411665 Rev.05 - 06/2016...
  • Page 2 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 COMPONENTS TECHNICAL SPECIFICATIONS Control unit power supply: 230 Vac Single-phase Absorption in stand by: 30 mA Environment temperature : -20°C +50°C...
  • Page 3 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 CONNECTIONS RADIO MODULE RF FIX (CNS) 24V (Red) Limit switch Closing 1 (Yellow) 14 15 16 17 18 19 20 RF FIX...
  • Page 4 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 PROGRAMMING PROGRAMMING QUICK START BUTTONS MENU MENU LANGUAGE ITALIANO DOWN Skip this step if you do not want to program a transmitter...
  • Page 5 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 MENU FUNCTIONS TABLE GATE 1 DG R2BF MENU Default Set value Description Italiano Italian English English English 1 - LANGUAGE Français...
  • Page 6: Function Logic

    ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 WORKING TIMES SELF LEARNING 1) Turn off electricity, release the motors and manually position the leaves on halfway. Reset the mechanical lock.
  • Page 7: Special Menu

    PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU DOWN SPECIAL MENU FUNCTIONS TABLE GATE 1 DG R2BF INVERTER For entering into the special menu move on one of the menu and press the UP and DOWN buttons at the same time for 5 s.
  • Page 8 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 MENU SP Description Default Set Value Adjust the passage between normal speed 63 - DECELERATION 100% and slowdown speed Acceleration ramp.
  • Page 9 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 MENU SP Description Default Set Value AUX output always Always power supplied output active only In cycle during cycle AUX output power...
  • Page 10 If the password has been forgotten, the only way to unlock the control unit is to contact the SEA technical assistance, which will assess whether to provide the procedure to unlock the control unit or not.
  • Page 11 Photocell 1 Edge Photocell 2 DOWN MENU FUNCTION TABLE CHECK GATE 1 DG R2BF INVERTER INPUTS To access the Menu for input check keep pressed OK for about 5 seconds. Description Description MENU The contact must be a N.O. Contact . When activating the related command START on the display SET lights up, the input works.
  • Page 12 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 RADIO TRANSMITTER SELF LEARNING WITH RECEIVER ON BOARD OF CONTROL UNIT WARNING: Make the radio transmitters programming before you connect the antenna and insert the receiver into the special CMR connector (if available) with turned off control unit.
  • Page 13 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 RADIO TRANSMITTER SELF LEARNING WITH RF FIX RECEIVER ON BOARD OF CONTROL UNIT WARNING: Make the radio transmitters programming before you connect the antenna and insert the receiver into the special CNS connector (if available) with turned off control unit.
  • Page 14 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 START - STOP - PEDESTRIAN START - ANTENNA - PHOTOCELL Photocell 1 and Photocell 2 Connections Note: If the photocells are not connected, it is not necessary put a jumper between the clamps (6 and 7...
  • Page 15 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 AMPEROMETRIC MANAGEMENT AMPEROMETRIC DEVICE FOR ELECTROMECHANICAL OPERATORS This control unit comes with an obstacle detection system working only on electromechanical operators allowing to have the reversing on obstacles and the automatic detection of the stops.
  • Page 17 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 FOUR LIMIT SWITCH WITH LSE CARD Dip switch 1 = OFF Dip switch 2 = ON GATE1 DG INV CONTROL UNIT On the GATE1 DG INV to activate the EXT mode on Limit Switch Menu.
  • Page 18 ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 INVERTER MODULE CONNECTION (Already wired) 230Vac Three phase 380Vac Three phase+N R S T N R S T INVERTER MODULE U V W...
  • Page 19: Alarm Description

    ® GATE 1 DG R2BF English Sistemi Elettronici INVERTER di Apertura Porte e Cancelli International registered trademark n. 804888 ALARM DESCRIPTION Signals Kind of alarm Solutions Inverter failure Check the connections between Gate 1 DG and inverter module. FAILURE INVERTER...
  • Page 20: Troubleshooting

    Materials handling must be made with appropriate vehicles.. WARRANTY LIMITS For the guarantee see the sales conditions on the official SEA price list. SEA reserves the right to make any required modification or change to the products and/or to this manual without any advanced notice obligation.
  • Page 21 The recognized defects, whatever their nature, shall not produce any responsibility and/or damage claim on the part of the Buyer against SEA. The guarantee is in no case recognized if changes are made to the goods, or in the case of improper use, or in the case of tampering or improper assembly, or if the label affixed by the manufacturer has been removed including the SEA registered trademark No.
  • Page 22 3. This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the good condition/operation of the product and/or be a source of danger. SEA S.p.A. declines all liability caused by improper use or different use in respect to the intended one.
  • Page 23 è stato testato singolarmente al fine di garantire i più alti livelli qualitativi e la vostra soddisfazione. Vi ringraziamo per aver scelto SEA. This item has been produced following strict production procedures and has been singularly tested for the highest quality levels and for your complete satisfaction.
  • Page 24 ® Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 SEA S.p.A. Zona industriale 64020 S.ATTO Teramo - (ITALY) Tel. +39 0861 588341 r.a. Fax +39 0861 588344 www.seateam.com seacom@seateam.com...

This manual is also suitable for:

23001235