SEA full tank Installation Instructions Manual

SEA full tank Installation Instructions Manual

Hydraulic operator for swing gate

Advertisement

Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
ATTUATORE OLEODINAMICO PER CANCELLI A BATTENTE
HYDRAULIC OPERATOR FOR SWING GATE
ACTUATEUR HYDRAULIQUE POUR PORTAIL À BATTANTS
ACTUADOR OLEODINAMICO PARA CANCELAS ABATIBLES
Cod. 67410845
®
FULL TANK
MANUALE D`INSTALLAZIONE
ed informazioni sulla sicurezza
INSTALLATION MANUAL
and Security Information
REV 08 - 04/2015
Italiano
Italiano
English
English
Fran ais
Français
Español
Español

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the full tank and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SEA full tank

  • Page 1 Español Español ATTUATORE OLEODINAMICO PER CANCELLI A BATTENTE HYDRAULIC OPERATOR FOR SWING GATE ACTUATEUR HYDRAULIQUE POUR PORTAIL À BATTANTS ACTUADOR OLEODINAMICO PARA CANCELAS ABATIBLES FULL TANK MANUALE D`INSTALLAZIONE ed informazioni sulla sicurezza INSTALLATION MANUAL and Security Information Cod. 67410845 REV 08 - 04/2015...
  • Page 2: Features And Specifications

    Apertura Porte e Cancelli FEATURES AND SPECIFICATIONS The FULL TANK is a high quality hydraulic operator for condominium use for gates with leaf lengths up to max. 7 m. Available in the following versions: AC (with lock in opening and closing position)
  • Page 3 ® FULL TANK English English Sistemi Elettronici di Apertura Porte e Cancelli...
  • Page 4: Typical Installation

    Antenna 10. Column for photocells 11. Warning notice 12. Safety Gate TYPE OF INSTALLATION It is possible to install the Full Tank with opening inside (Fig.5) or opening outside (Fig.6 Inward installation Outward installation Outside Outside Install the operator always inside the property.
  • Page 5 ® FULL TANK English English Sistemi Elettronici di Apertura Porte e Cancelli INSIDE OPENING INSTALLATION Total stroke 270 mm - max. recommended stroke 250 mm Max. Outside Max. Stroke Stroke Opening (mm) (mm) (mm) (mm) for 90°(mm) Angle 110° 90°...
  • Page 6 ® FULL TANK English English Sistemi Elettronici di Apertura Porte e Cancelli OUTSIDE OPENING INSTALLATION Outside Total stroke 270 mm - max. recommended stroke 250 mm Max. Stroke Stroke Opening max (mm) for 90°(mm) (mm) (mm) Angle 95° 90° 95°...
  • Page 7: Installation On Masonry Pillars, Making A Niche

    ® FULL TANK English English Sistemi Elettronici di Apertura Porte e Cancelli INSTALLATION ON MASONRY PILLARS, MAKING A NICHE * 1180 60 Min. 155 Min. ** 1415 * Version 270 mm ** Version 390 mm If you have to make a niche observe the dimensions shown in fig.9.
  • Page 8 ® FULL TANK English English Sistemi Elettronici di Apertura Porte e Cancelli INSTALLATION OF THE OSCILLATING REAR BRACKET PRELIMINARY: - Open carefully the package, making sure not to loose parts which are listed in fig. 4. - Attach the rear oscillating bracket as shown in fig.
  • Page 9 ® FULL TANK English English Sistemi Elettronici di Apertura Porte e Cancelli POSITIONING OF THE FRONT BRACKET Once the operator is attached to the post and the leaf set in the closed position execute the following operations: 1. Release the operator.
  • Page 10 Attention: The mounting of the mechanical positive stops does not cause the reduction of the shaft stroke. rods parallel to the gate Disc 2 Disc 1 Fig. 20 FULL TANK WITH SEPARATE HYDRAULIC UNIT Flexible tube 2 0 - 3 9 9 8 0 * ( F u ll...
  • Page 11 ® FULL TANK English English Sistemi Elettronici di Apertura Porte e Cancelli BREATHER SCREW ATTENTION It is obligatory to remove the breather screw at the end of the installation. Fig. 22 Unscrew and remove the screw under the operator at the end of installation Fig.
  • Page 12: Oil Level Measurement

    Apertura Porte e Cancelli OIL LEVEL MEASUREMENT Oil level Fig. 26 The oil level should be measured with the rod inserted into the actuator and must stand in accordance with the distributor. FULL TANK ACCESSORIES KEY SWITCH PHOTOCELLS TRANSMITTER RADIO RECEIVER SAFETY GATE...
  • Page 13: Risk Examination

    INITIAL TEST AND STARTING OF THE AUTOMATION After having completed the necessary operations for a correct installation of the Full Tank product, as described in this manual, and after having valuated all resting risks which could arise in any installation, it is necessary to test the automation to guaranty...
  • Page 14: Periodical Maintenance

    1) Check the solidity and the stability of the gate, especially the points of support and/or rotation of Annual the gate (pivots). 2) Check the oil level of the hydraulic/in oil bath operators (cap on rear cover of the Full Tank) Annual 3) Change the hydraulic oil with the one recommended from the head company...
  • Page 15 5) DELIVERY Delivery shall take place, approximately and not peremptorily, within 30 working days from the date of receipt of the order, unless otherwise notified. Transport of the goods sold shall be at Buyer’s cost and risk. SEA shall not bear the costs of delivery giving the goods to the carrier, as chosen either by SEA or by the Buyer. Any loss and/or damage of the goods during transport, are at Buyer’s cost.
  • Page 16 14. Transit through the leaves is allowed only when the gate is fully open. 15. The User must not attempt to repair or to take direct action on the system and must solely contact qualified SEA personnel or SEA service centers. User can apply only the manual function of emergency.
  • Page 17 3. Este producto fue diseñado y construido exclusivamente para el uso especificado en esta documentación. Cualquier otro uso no expresamente indicado puede afectar la integridad del producto y ser una fuente de peligro. El uso inadecuado es también causa de anulación de la garantía. SEA S.p.A. se exime de toda responsabilidad causadas por uso inapropiado o diferente de aquel para el que el sistema automatizado fue producido.
  • Page 18 La SEA S.p.A. dichiara sotto la propria responsabilità e, se applicabile, del suo rappresentante autorizzato che il prodotto: SEA S.p.A. declares under its proper responsability and, if applicable, under the responsability of its authorised representative that the product: Descrizione / Description...
  • Page 19 N.B: L’estensione della garanzia legale di 12 mesi a 24 mesi e 36 mesi è va- lida solo se il presente modulo viene rispedito per posta o fax a SEA S.p.A. entro 15gg dalla data di acquisto. Allegare relativa fattura d’acquisto.
  • Page 20 ® Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 SEA S.p.A. Zona industriale 64020 S.ATTO Teramo - (ITALY) Tel. +39 0861 588341 r.a. Fax +39 0861 588344 www.seateam.com seacom@seateam.com...

Table of Contents