send send-times: Specifies the maximum number of accounting-on packet transmission attempts. The
value range for the send-times argument is 1 to 255, and the default setting is 50.
Usage guidelines
The accounting-on feature enables the device to automatically send an accounting-on packet to the
RADIUS server after a device or card reboot. Upon receiving the accounting-on packet, the RADIUS
server logs out all online users so they can log in again through the device.
Execute the save command to make sure the accounting-on enable command takes effect at the next
reboot. For information about the save command, see Fundamentals Command Reference.
Parameters set with the accounting-on enable command take effect immediately.
Examples
# Enable the accounting-on feature for RADIUS scheme radius1, and set the retransmission interval to 5
seconds and the transmission attempts to 15.
<Sysname> system-view
[Sysname] radius scheme radius1
[Sysname-radius-radius1] accounting-on enable interval 5 send 15
Related commands
display radius scheme

data-flow-format (RADIUS scheme view)

Use data-flow-format to set the data flow and packet measurement units for traffic statistics.
Use undo data-flow-format to restore the default.
Syntax
data-flow-format { data { byte | giga-byte | kilo-byte | mega-byte } | packet { giga-packet |
kilo-packet | mega-packet | one-packet } } *
undo data-flow-format { data | packet }
Default
Traffic is counted in bytes and packets.
Views
RADIUS scheme view
Predefined user roles
network-admin
Parameters
data { byte | giga-byte | kilo-byte | mega-byte }: Specifies the unit for data flows, which can be byte,
kilobyte, megabyte, or gigabyte.
packet { giga-packet | kilo-packet | mega-packet | one-packet }: Specifies the unit for data packets,
which can be one-packet, kilo-packet, mega-packet, or giga-packet.
Usage guidelines
The data flow and packet measurement units for traffic statistics must be the same as configured on the
RADIUS accounting servers. Otherwise, accounting results might be incorrect.