7.1.070-Test 0001016
Incompatible upgrade.
The output shows that the two versions are incompatible. The member devices will be rebooted for
the upgrade.
# Upgrade the feature on the subordinate member.
<Sysname> issu load file feature flash:/feature1-t0001016.bin slot 2
This operation will delete the rollback point information for the previous upgrade and
maybe get unsaved configuration lost. Continue? [Y/N]:y
Verifying the file flash:/feature1-t0001016.bin on slot 1...Done.
Copying file flash:/feature1-t0001016.bin to
slot2#flash:/feature1-t0001016.bin......Done.
Verifying the file flash:/feature1-t0001016.bin on slot 2...Done.
Identifying the upgrade methods...Done.
Upgrade summary according to following table:
flash:/feature1-t0001016.bin
Running Version
Test 0001015
Slot
2
Upgrading software images to incompatible versions. Continue? [Y/N]:y
This operation might take several minutes, please wait...Done.
# Upgrade the feature on the original master.
<Sysname> issu run switchover
Upgrade summary according to following table:
flash:/feature1-t0001016.bin
Running Version
Test 0001015
Slot
1
Upgrading software images to incompatible versions. Continue? [Y/N]:y
This operation might take several minutes, please wait...Done.
# Verify that both members are running the new feature image.
<Sysname> display install active
Active packages on slot 1:
flash:/boot-t0001015.bin
flash:/system-t0001015.bin
flash:/feature1-t0001016.bin
Active packages on slot 2:
flash:/boot-t0001015.bin
flash:/system-t0001015.bin
flash:/feature1-t0001016.bin
New Version
Test 0001016
Upgrade Way
Reboot
New Version
Test 0001016
Upgrade Way
Reboot