Step 1: Physical Installation - Emerson Rosemount 708 Quick Installation Manual

Wireless acoustic transmitter
Hide thumbs Also See for Rosemount 708:
Table of Contents

Advertisement

Quick Installation Guide
00825-0200-4708, Rev AD
April 2012
S
1: P
TEP
HYSICAL
The acoustic transmitter is connected directly to the piping that is being measured.
Mounting
1. Locate the 708 on a horizontal section of piping as close as possible to the equipment to
be monitored. Align the waveguide of the transmitter as shown in Figure 3 and Figure 4.
2. The mounting location should be free of foreign matter and corrosion to ensure good
contact between the piping and the waveguide.
3. Tighten each clamp to 90 in-lb (10.2 N-m). Trim the excess clamp band material to
prevent unwanted acoustic noise.
4. If commissioning the device, install the green Power Module (see Figure 5).
5. Ensure that the Power Module cover is fully tightened to prevent moisture ingress. The
lip of the polymer Power Module cover should be in contact with the surface of the
polymer enclosure to ensure a proper seal. Do not over tighten.
Figure 3. Transmitter Alignment
Figure 4. Transmitter Alignment Top View
I
NSTALLATION
Rosemount 708
5

Advertisement

Table of Contents
loading

Table of Contents