Cold Start Trap Broadcast—Cold Start Trap is broadcast to a subnet broadcast address if there are
no trap destinations configured in the SNMP Alert Destination(s) boxes. The subnet broadcast address
for an IPv4 host is obtained by performing a bitwise logical OR operation between the bit complement
of the subnet mask and the host IP address. For example, the host 192.168.1.1, which has the subnet
mask 255.255.252.0, has the broadcast address 192.168.1.1 | 0.0.3.255 = 192.168.3.255.
SNMPv1 Traps—When enabled, SNMPv1 traps are sent to the remote management systems
configured in the SNMP Alert Destination(s) boxes.
To edit the settings on the SNMP Alerts tab:
In the iLO Configuration Utility window, click Management. The SNMP Settings tab data appears.
Click the SNMP Alerts tab.
Click the radio button to select the Trap Source Identifier.
Click the drop-down list by each setting to select to enable or disable the setting.
If you choose to send an alert, click Send Test Alert.
Click Apply.
Management — Insight Management Integration
HPE System Management Homepage (HPE SMH) FQDN/IP Address—This value sets the browser
destination of the Insight Agent link on iLO pages. Enter the FQDN or IP address of the host server.
The protocol (https://) and port number (:2381) are added automatically to the IP address or
DNS name to allow access from iLO. If the URL is set through another method (for example,
CPQLOCFG), click the browser refresh button to display the updated URL.
Level of Data Returned—This setting controls the content of an anonymous discovery message
received by iLO. The information returned is used for HPE SIM HTTP identification requests. The
following options are available:
Enabled (iLO+Server Association Data) (default)—Enables HPE SIM to associate the
management processor with the host server, and provides sufficient data to enable integration with
HPE SIM.
Disabled (No Response to Request)—Prevents iLO from responding to HPE SIM requests.
To edit the settings on the Insight Management Integration tab:
In the iLO Configuration Utility window, click Management. The SNMP Settings tab data appears.
Click the Insight Management Integration tab. The Insight Management Integration tab data is
displayed.
Edit the setting(s) that you want. Click Apply.