4. Diagnostics
Order Code
Synopsis: Any 57 characters
Shows the order code of the device.
Classification
Synopsis: Any 15 characters
Provides system classification.
The value 'Controlled' indicates the main firmware is a Controlled release. The value 'Non-
Controlled' indicates the main firmware is a Non-Controlled release. The 'Controlled' main
firmware can run on Controlled units, but it can not run on Non-Controlled units. The 'Non-
Controlled' main firmware can run on both Controlled and Non-Controlled units.
Serial Number
Synopsis: 31 characters
Shows the serial number of the device.
Boot Version
Synopsis: 47 characters
Shows the version and the build date of the boot loader software.
Main Version
Synopsis: 47 characters
Shows the version and build date of the main operating system software.
Hardware ID
Synopsis: { RSMCPU (40-00-0008 Rev B1), RSMCPU2 (40-00-0026 Rev
A1), RS400 (40-00-0010 Rev B2), RMC30, RS900 (40-00-0025 Rev
B1), RS900 (40-00-0032 Rev B1), RS1600M, RS400 (40-00-0010 Rev
C1), RSG2100, RS900G, RSG2200, RS969, RS900 (v2, 40-00-0066),
RS900 (v2, 40-00-0067), , RS416 (40-00-0078), RMC30 (v2), RS930
(40-00-0089), RS969 (v2, 40-00-0090), RS910 (40-00-0091-001 Rev
A), RS920 (40-00-0102-001 Rev A), RS940G (40-00-0097-000 Rev A),
RSi80X series CPU board, RSG2300, RS416v2, ... }
Shows the type, part number, and revision level of the hardware.
4.5. Loading Factory Default Configuration
The Load Factory Defaults menu is used to reset the unit's configuration to its factory default.
Optionally, it is possible to exclude parameters that affect basic connectivity and SNMP
management from the reset in order to be able to remain in communication with the device.
Specifically, configuration items in the following categories are not affected by a selective
configuration reset:
• IP Interfaces
• IP Gateways
• SNMP Users
• SNMP Security to Group Maps
• SNMP Access
• RuggedCom Discovery Protocol™ (RCDP)
• Time Zone
ROS® v3.11User Guide
95
RMC30
Need help?