Appendix F. Security Messages for Authentication
Message Name
Failed Login
User Logout
Table F.2. Configurable Options
Excessive Failed Login Attempts
ROS® generates this alarm and logs a message in the syslog after 10 failed login attempts
by a user.
Message Name
Excessive
Failed
Login
Attempts
Table F.3. Configurable Options
RADIUS Server Unreachable
ROS® generates this alarm and logs a message in the syslog when the primary RADIUS
server is unreachable.
Message Name
Primary RADIUS Server
Unreachable
Table F.4. Configurable Options
TACACS Server Unreachable
ROS® generates this alarm and logs a message in the syslog when the primary TACACS
server is unreachable.
Message Name
Primary TACACS Server
Unreachable
Table F.5. Configurable Options
TACACS Response Invalid
ROS® generate this alarm and logs a message in the syslog when the response from the
TACACS server is received with an invalid CRC.
Message Name
TACACS Response Invalid Yes
Table F.6. Configurable Options
SNMP Authentication Failure
ROS® generates this alarm, sends an authentication failure trap, and logs a message in the
syslog when an SNMP manager with incorrect credentials communicates with the SNMP agent
in ROS®.
ROS® v3.11User Guide
Alarm
Yes
No
Alarm
Yes
Alarm
Yes
Alarm
Yes
Alarm
136
SNMP Trap
Yes
No
SNMP Trap
Yes
SNMP Trap
Yes
SNMP Trap
Yes
SNMP Trap
Yes
Syslog
Yes
Yes
Syslog
Yes
Syslog
Yes
Syslog
Yes
Syslog
Yes