APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 37 of 55)
ADDR
REGISTER NAME
A732
...Repeated for Non-Volatile Latch 6
A73C
...Repeated for Non-Volatile Latch 7
A746
...Repeated for Non-Volatile Latch 8
A750
...Repeated for Non-Volatile Latch 9
A75A
...Repeated for Non-Volatile Latch 10
A764
...Repeated for Non-Volatile Latch 11
A76E
...Repeated for Non-Volatile Latch 12
A778
...Repeated for Non-Volatile Latch 13
A782
...Repeated for Non-Volatile Latch 14
A78C
...Repeated for Non-Volatile Latch 15
A796
...Repeated for Non-Volatile Latch 16
Digital Counter (Read/Write Setting) (8 modules)
A800
Digital Counter 1 Function
A801
Digital Counter 1 Name
A807
Digital Counter 1 Units
A80A
Digital Counter 1 Block
A80B
Digital Counter 1 Up
A80C
Digital Counter 1 Down
A80D
Digital Counter 1 Preset
A80F
Digital Counter 1 Compare
A811
Digital Counter 1 Reset
A812
Digital Counter 1 Freeze/Reset
A813
Digital Counter 1 Freeze/Count
A814
Digital Counter 1 Set To Preset
A815
Reserved (11 items)
A820
...Repeated for Digital Counter 2
A840
...Repeated for Digital Counter 3
A860
...Repeated for Digital Counter 4
A880
...Repeated for Digital Counter 5
A8A0
...Repeated for Digital Counter 6
A8C0
...Repeated for Digital Counter 7
A8E0
...Repeated for Digital Counter 8
Frequency Rate of Change (Read/Write Setting) (4 modules)
A900
Frequency Rate of Change 1 Function
A901
Frequency Rate of Change 1 OC Supervision
A902
Frequency Rate of Change 1 Min
A903
Frequency Rate of Change 1 Max
A904
Frequency Rate of Change 1 Pickup Delay
A905
Frequency Rate of Change 1 Reset Delay
A906
Frequency Rate of Change 1 Block
A907
Frequency Rate of Change 1 Target
A908
Frequency Rate of Change 1 Events
A909
Frequency Rate of Change 1 Source
A90A
Frequency Rate of Change 1 Trend
A90B
Frequency Rate of Change 1 Pickup
A90C
Frequency Rate of Change 1 OV Supervision
A90D
Frequency Rate of Change 1 Reserved (3 items)
A910
...Repeated for Frequency Rate of Change 2
A920
...Repeated for Frequency Rate of Change 3
A930
...Repeated for Frequency Rate of Change 4
IEC 61850 received analog settings (read/write)
AA00
IEC 61850 GOOSE analog 1 default value
AA02
IEC 61850 GOOSE analog input 1 mode
GE Multilin
RANGE
0 to 1
---
---
0 to 65535
0 to 65535
0 to 65535
–2147483647 to
2147483647
–2147483647 to
2147483647
0 to 65535
0 to 65535
0 to 65535
0 to 65535
---
0 to 1
0 to 30
20 to 80
20 to 80
0 to 65.535
0 to 65.535
0 to 65535
0 to 2
0 to 1
0 to 5
0 to 2
0.1 to 15
0.1 to 3
0 to 1
–1000000 to 1000000
0 to 1
F60 Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
---
F205
---
---
F206
---
1
F300
---
1
F300
---
1
F300
---
1
F004
---
1
F004
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
---
F001
---
1
F102
pu
0.001
F001
Hz
0.01
F001
Hz
0.01
F001
s
0.001
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F167
---
1
F224
Hz/s
0.01
F001
pu
0.001
F001
---
1
F001
---
0.001
F060
---
1
F491
0 (Default Value)
DEFAULT
B
0 (Disabled)
"Counter 1"
(none)
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
200
4500
6500
0
0
0
0 (Self-reset)
0 (Disabled)
0 (SRC 1)
0 (Increasing)
50
700
0
1000
B-45