APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 23 of 55)
ADDR
REGISTER NAME
5EC1
Incipient cable fault detector 1 phase B counter
5EC2
Incipient cable fault detector 1 phase C counter
5EC3
...Repeated for incipient cable fault detector 2
Setting Groups (Read/Write Setting)
5F80
Setting Group for Modbus Comms (0 means group 1)
5F81
Setting Groups Block
5F82
FlexLogic to Activate Groups 2 through 6 (5 items)
5F89
Setting Group Function
5F8A
Setting Group Events
Setting Groups (Read Only)
5F8B
Current Setting Group
Setting Group Names (Read/Write Setting)
5F8C
Setting Group 1 Name
5F94
Setting Group 2 Name
5F9C
Setting Group 3 Name
5FA4
Setting Group 4 Name
5FAC
Setting Group 5 Name
5FB4
Setting Group 6 Name
Wattmetric ground fault settings (read/write grouped, 2 modules)
6050
Wattmetric ground fault 1 function
6051
Wattmetric ground fault 1 source
6052
Wattmetric ground fault 1 voltage
6053
Wattmetric ground fault 1 overvoltage pickup
6054
Wattmetric ground fault 1 current
6055
Wattmetric ground fault 1 overcurrent pickup
6056
Wattmetric ground fault 1 overcurrent pickup delay
6057
Wattmetric ground fault 1 power pickup
6058
Wattmetric ground fault 1 ECA
6059
Wattmetric ground fault 1 power pickup delay
605A
Wattmetric ground fault 1 curve
605B
Wattmetric ground fault 1 multiplier
605C
Wattmetric ground fault 1 block
605D
Wattmetric ground fault 1 target
605E
Wattmetric ground fault 1 events
605F
Wattmetric ground fault 1 reference power
6060
Reserved
6061
...Repeated for wattmetric ground fault 2
Wattmetric ground fault actual values (read only)
6072
Wattmetric ground fault 1 operating power
6074
Wattmetric ground fault 2 operating power
Autoreclose (Read/Write Setting) (6 modules)
6240
Autoreclose 1 Function
6241
Autoreclose 1 Initiate
6242
Autoreclose 1 Block
6243
Autoreclose 1 Max Number of Shots
6244
Autoreclose 1 Manual Close
6245
Autoreclose 1 Manual Reset from LO
6246
Autoreclose 1 Reset Lockout if Breaker Closed
6247
Autoreclose 1 Reset Lockout On Manual Close
6248
Autoreclose 1 Breaker Closed
6249
Autoreclose 1 Breaker Open
624A
Autoreclose 1 Block Time Upon Manual Close
624B
Autoreclose 1 Dead Time Shot 1
624C
Autoreclose 1 Dead Time Shot 2
GE Multilin
RANGE
0 to 65535
0 to 65535
0 to 5
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 5
---
---
---
---
---
---
0 to 1
0 to 5
0 to 1
0.02 to 3.00
0 to 1
0.002 to 30.000
0 to 600
0.001 to 1.2
0 to 360
0 to 600
0 to 5
0.01 to 2
0 to 65535
0 to 2
0 to 1
0.001 to 1.2
---
0.000 to 1000000.000
0.000 to 1000000.000
0 to 1
0 to 65535
0 to 65535
1 to 4
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 655.35
0 to 655.35
0 to 655.35
F60 Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F001
---
1
F300
---
1
F300
---
1
F102
---
1
F102
---
1
F001
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
1
F102
---
1
F167
---
1
F234
0 (Calculated VN)
pu
0.01
F001
---
1
F235
pu
0.001
F001
s
0.01
F001
pu
0.001
F001
° Lag
1
F001
s
0.01
F001
---
1
F236
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
pu
0.001
F001
---
---
---
W
0.001
F060
W
0.001
F060
---
1
F102
---
1
F300
---
1
F300
---
1
F001
---
1
F300
---
1
F300
---
1
F108
---
1
F108
---
1
F300
---
1
F300
s
0.01
F001
s
0.01
F001
s
0.01
F001
DEFAULT
0
0
0
B
0
0
0 (Disabled)
0 (Disabled)
0
(none)
(none)
(none)
(none)
(none)
(none)
0 (Disabled)
0 (SRC 1)
20
(Calculated IN)
60
20
100
0
20
0 (Definite Time)
100
0
0 (Self-reset)
0 (Disabled)
500
---
0
0
0 (Disabled)
0
0
1
0
0
0 (Off)
0 (Off)
0
0
1000
100
200
B-31