11.2.6.
Byte
Bit
Status bit
0
0
HV display ON
1
Reserve
2
Collective error / switch off
3
Collective warning
4
The high voltage is safety off.
CAUTION:
This SW bit does not fulfill the Per-
formance Level, this is only
achieved by HW feedback.
5
Reserve
6
Drive power status
7
Monitoring contact status
1
0
Heartbeat
1
Reserve
2
Reserve
3
Reserve
4
Warning: invalid parameters
5
Imax warning
6
Reserve
7
Reserve
Operating manual 810378-BAL-EN-170330

Description of the status word

Mach/30 2017
Description
Mirror bit of the HV EIN bit
higher)
1: For error or switch off
0: no error
1: For warning
0: No warning
1: If the high voltage has been
switched off and the output voltage
has discharged to a safe level.
0: If the high voltage is switched on /
or the output voltage has not been
discharged to a safe level
0: If a self-test error of the device has
been detected
1: 24 V DRIVE is on
0: 24 V DRIVE is not on
1: Relay contact open
0: Relay contact closed
This Bit is switched every second
between 1 (logic high) and 0 (logic
low) to display that the HV-supply is
still active.
1: An invalid parameter (value
outside of range) has been received.
0: parameter valid
1: I actual is above 80 % of Imax
0: I actual is below 80 % of Imax
(V2.01 and