Hs-Erzeuger Mit Can-Bus-Schnittstelle - SCHNIER smart-E 310 Operating Manual

High-voltage supply
Table of Contents

Advertisement

5.2. HS-Erzeuger mit CAN-BUS-Schnittstelle

(supplies with PROFINET, Ethernet/IP or EtherCAT see 5.3)
This picture shows the orientation of the M12 connectors on the front of the
supply.
Drive
Ground
CAN/CPU
5.2.1.
The CAN-Interface is a 5-pole A-coded plug. It contains CAN-bus wires and the 24 V
power for the Controller (CPU).
2
5
3
5.2.2.
The supply connection is a 5-pin M12 B-coded plug.
It carries the following signals:
1) Supply for the HV generator (24V-DRIVE)
2) Monitoring contact (relay closed, if the HV system is discharged)
2
5
3
Operating manual 810378-BAL-EN-170330
Bus interface
Pin
1
1
2
3
4
4
5
Screw
Supply Connection
Pin
1
1
2
3
4
4
5
Screw
Signal
GND
24 V CPU
GND
CAN-H
CAN-L
Shield
Signal
Monitoring contact
24 V CPU (do not use!)
GND
24V Drive
Monitoring contact
Shield
Mach/30 2017
Symbol
CAN
Symbol
Page 20 of 54