High-voltage supply
Table of Contents

Advertisement

10.2.Application interface

10.2.1.
Byte 0
Byte 1
Control word
Byte
Byte
10
11
kV ramp
10.2.2.
Byte 0
Byte 1
Status word
Byte
Byte
10
11
Reserve
10.2.3.
Data
Unit
U target
kV
U min
kV
I Limit*
uA
I max.*
uA
U actual
100
V
I actual
uA
kV-ramp
kV/s
*
Sensitivity
of the electrical
arc detection
*: Valid from SW version 3.0. Of that: 550uA
Values outside of these areas (min, max) are ignored. The warning "invalid parame-
ters" is output.
Caution: The Byte sequence is Little-Endian. The Byte sequence can be taken from the
following examples:
Operating manual 810378-BAL-EN-170330

Receive I/O data mapping (EIP controller to Smart-E510)

Byte 2
Byte 3
Byte 4
U target value
U min (kV)
(kV)
Byte
Byte
Byte
12
13
14
*
Sensitivity

I/O data mapping transfer: (Smart-E510 to EIP-Controller)

Byte 2
Byte 3
Byte 4
Service code
Byte
Byte
Byte
12
13
14
Sub-Version
Main-Version

I/O data definition (area, unit, standard)

Mi
Max smart-E
n
310
10
100
10
100
10
300
10
300
0
1095
0
667
10
100
0
10
Typically this parameter can be set to 5.
Do not switch off electrical arc detection in normal operation!!
Byte 5
Byte 6
Byte 7
I Limit (uA)
Byte
Byte
15
16
Reserve
Byte 5
Byte 6
Byte 7
U actual (100V)
Byte
Byte
15
16
HW Version
Max smart-E
Stan-
510
dard
0
0
800 / 600
0
0-80 kV – 800
81-100 kV - 600
800
0
1240
-
1130
-
0
0
Mach/30 2017
Byte 8
Byte 9
Imax (uA)
Byte
Byte
Byte
17
18
19
Byte 8
Byte 9
I actual (uA)
Byte
Byte
Byte
17
18
19
Reserve
Remark
kV target val-
ue/limiting value
Limit value for
Umin-switch off
Target value for
current limiting
value (800 below
80 kV)
Limit value for Imax
- switch off
Actual value kV
Actual current
Speed when start-
ing up voltage
0: Electrical arc
detection off
1~10: Highest to
lowest sensitivity,
Page 44 of 54