8.2.7.
Byte
Bit
0
0
High voltage ON
1
Reset error
2
Reserve
3
Reserve
4
Relay test bit
5..7
Reserve
1..3
0...7 Reserve
8.2.8.
Byte
Bit
Status bit
0
0
HV display ON
1
Collective error / switch off
2
Collective warning
3
The high voltage is safety off.
CAUTION:
This SW bit does not fulfill the
Performance Level, this is only
achieved by HW feedback.
4
Drive power status
5
Monitoring contact status
6..7
Reserve
Operating manual 810378-BAL-EN-170330
Describing the control word
Control bit
Description of the status word
Mach/30 2017
Description
1: Switch on high voltage
0: Switch off high voltage
1: All errors are confirmed
0: No action
Note: In order to switch on HV
again, after an error has been con-
firmed, the "HV ON" bit must be re-
set/set.
1: Open the safety relay
0: No action / close relay
Note: The safety relay is controlled
by the HV generator depending on
the remaining voltage on the HV
connection.
If the contact is found in the "safe"
position (closed), it can be opened
with this Bit for test purposes.
Note: When the relay test bit is set,
the HV cannot be switched on.
Description
1: HV creation is switched on
0: HV creation is switched off
1: For error or switch off
0: No error
1: For warning
0: No warning
1: If the high voltage has been
switched off and the output voltage
has discharged to a safe level.
0: If the high voltage is switched on /
or the output voltage has not been
discharged to a safe level
0: If a self-test error of the device has
been detected
1: 24 V DRIVE is on
0: 24 V DRIVE is not on
1: Relay contact open
0: Relay contact closed
Page 36 of 54