Profinet Interface Specifications; Application Interface; Gsd-Files; Write The Data Sets (Record Writes) - SCHNIER smart-E 310 Operating Manual

High-voltage supply
Table of Contents

Advertisement

9.

PROFINET interface specifications

(smart-E 310p, smart-E510p, smart-E 310Dp, smart-E 510Dp)
9.1. Bus interface
Profinet based on the ethernet physical layer. To create communication between the
smart-E 310 or smart-E 510 and profinet controller (PN controller), no special steps are
required. The IP address is set automatically. See the manual of your PN controller for
further information. For examples of setting up communications, see our smart-E
website www.smart-E310.de.

9.2. Application interface

9.2.1.
9.2.2.
The user interface uses datasets (records) for two parameter settings of the HV gener-
ator:
Byte
Parameters
0
kV ramp
1
Sensitivity of
electrical arc
detection
2..15
Reserve
Operating manual 810378-BAL-EN-170330

GSD-Files

Use our standardized "GSD" files to load the applications interface
to your control software.
GSD files are simple text files that use network configuration tools
to support the identification of products and their simple direction in
a network.
SCHNIER provides a GSD file with all parameters and format in-
formation of the HV generator. It can be obtained on the smart-E
website www.smart-E310.de.

Write the data sets (record writes)

Unit
Min
kV/s
1
-
0
As usual this parameter could be unchanged.
Do not switch off electrical arc detection in normal operation!
Stand-
max
Remarks
ard
20
100
Speed when starting up
voltage
5
10
0: Electrical arc detection
off
1~10: Highest to lowest
sensitivity.
Mach/30 2017
Page 38 of 54