I/O Data Definition (Area, Unit, Standard) - SCHNIER smart-E 310 Operating Manual

High-voltage supply
Table of Contents

Advertisement

11.2.4.
Data
Unit
U target
kV
U min
kV
I Limit*
uA
I max.*
uA
U actual
100
V
I actual
uA
kV-
kV/s
Rampe
*
Sensitivity
of the electrical
arc detection
Values outside of these areas (min, max) are ignored. The warning "invalid parame-
ters" is output.
Caution: The Byte sequence is Little-Endian. The Byte sequence can be taken from the
following examples:
Example: From a smart-E 510 received data:
Control word
HV ON
Byte 0
Byte 1
0x01
0x00
kV ramp
10 kV/s
Byte
Byte
10
11
0x0a
0x00
Example: From a smart-E 510 sent data:
Status word
Byte 0
Byte 1
0xC1
0x00
Operating manual 810378-BAL-EN-170330

I/O data definition (area, unit, standard)

Min
Max smart-
E 310
10
100
10
100
10
300
10
300
0
1095
0
667
10
100
0
Typically this parameter can be set to 5.
Do not switch off electrical arc detection in normal operation!
U Target value
U min
20 kV
5 kV
Byte 2
Byte 3
Byte 4
0x14
0x00
0x05
Sensitivity*
5
Byte
Byte
12
13
0x05
0x00
Service code
Byte 2
Byte 3
Byte 4
0x00
0x00
0x00
Max smart-E
Stan
510
dard
0
0
800 / 600
0
0-80 kV – 800
81-100 kV - 600
800
0
1240
-
1130
-
0
10
0
I Limit
256 uA
Byte 5
Byte 6
0x00
0x00
U actual
20 kV
Byte 5
Byte 6
0x00
0xC8
Mach/30 2017
Remarks
kV target val-
ue/limiting value
Limit value for Umin-
switch off
Target value for cur-
rent limiting value
(800 below 80 kV)
Limit value for Imax -
switch off
Actual value kV
Actual current
Speed when starting
up
voltage
0: Electrical arc de-
tection off
1~10: Highest to
lowest
sensitivity,
Imax
50 uA
Byte 7
Byte 8
Byte 9
0x01
0x32
0x00
I actual
10 uA
Byte 7
Byte 8
Byte 9
0x00
0x0A
0x00
Page 49 of 54