Grounding; High Voltage Connection - SCHNIER smart-E 310 Operating Manual

High-voltage supply
Table of Contents

Advertisement

5.4.

Grounding

In the first step the ground is connected. The high-voltage circuit is closed between the
HV generator and workpiece through the ground connection. The ground connection is
a standard M6 threaded bolt.
HV generator
HV ground screw / POAG

5.5.High Voltage Connection

In the second step the HV cable is attached.
Operating manual 810378-BAL-EN-170330
Sprayer system
as short a possible
WARNING
The ground wire must be as short as possible and have a cross-
section of at least 4 mm
current and bus lines.
The 4 mm pin of the HV cable must be completely pushed into the
HV jack in the HV generator. The cable screw fitting must be
properly tightened. Plug-in depth is 253 mm.
CAUTION
If shielded HV cables are used, the shielding must be removed
and the cable grounded.
CAUTION
To prevent ozone and oxidation from occurring, we recommend
greasing the connection.
If high voltage cables with internal conductors made of plastic are
used, then the cable may not be greased.
Workpiece
2
(AWG 11). Do not lay cable parallel to
Mach/30 2017
Page 22 of 54