Dräger X-am 1100 Technical Handbook page 43

Multi-gas
Table of Contents

Advertisement

— Always connect or disconnect the
charging modules individually and not in
groups in order to prevent the charging
station from becoming damaged. During
transportation, the power pack and the
charging modules should also always be
handled individually and without inserted
devices.
Position the device on an even and level
surface.
Connecting the power pack to the mains.
1 The green "Mains" LED lights.
Insert the device into the charging
module.
2 Display LED on the charger:
It takes approx. 4 hours to fully charge an
empty rechargeable battery.
A short circuit of the charging contacts in the
charging modules, e.g. by metallic objects
that have fallen in, does not result in damage
to the charging station. It should, however, be
avoided due to possible heating hazards and
incorrect displays on the charging module.
In the event of a short circuit or if the power
pack is overloaded:
3 The red "Overload" LED lights, and an
audible alarm sounds.
— After the fault has been corrected, the
alarm is switched off automatically and
the charging process is restarted.
— In the event of a power failure, the devices
already charged will be protected from
discharging.
Charge
Fault
Full
Maintenance
0
1 3
2
43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X-am 1700X-am 2000

Table of Contents