HP auroraTempo User Manual page 71

Table of Contents

Advertisement

Error Type
BPV
CRC (CRC framing only)
FAS
AIS
RAI
Highlight Line Error Rate and press ENTER to display
a sub-menu of available error types. Select the rate at
which errors are injected - these are shown in the
following table :
Error Rate
Single
2 in 5
DDS
DDS
1 in 1000
Continuous
DDS
DDS
2
Note
The error rates available depend on the error type you have
chosen.
Choose Inject Single or Start Injection (depending on
what is selected in Line Error Rate) from the BERT
Inject menu to start injecting errors.
Exit the sub-menus.
If you are injecting more than a single error, choose
Stop Injection to stop.
2
Note
The F5 function key toggles between Inject Single and
Start Injection depending on the Line Error Rate
selected.
Issue 1a - 10/99
Description
Injects a bi-polar violation error.
Injects a cyclic redundancy
error.
Injects a Frame Alignment
Signal error.
Injects Alarm Indication Signal errors.
Injects Remote Alarm Indication errors.
Description
Injects a single error.
Injects 2 errors in every 5 bits.
Injects 1 error in every 1000 bits.
Injects errors continuously.
Physical Testing
4-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

N1735a