HP auroraTempo User Manual page 149

Table of Contents

Advertisement

To set the time constant (Tc):
Highlight Tc [sec] and press the RIGHT arrow key to
display the Tc [sec] sub-menu.
Enter the time constant (Tc). This must be between 1
and 10.
Press ENTER to save and exit the Tc [sec] sub-menu.
The time constant is now displayed in the Setup Test
Config window.
Starting the test
Choose Start Test from the Frame Load Test Config
menu. The test begins and the test results are displayed
in the Test Results/Status window. This display is as
follows :
Frms Tx
Rx
Unknown
Lost
Err
Issue 1a - 10/99
Frame Relay Testing - Section 3
This is the number of frames
transmitted during the test.
This is the number of frames
received during the test.
This is the number of unrecognised
frames received during the test.
This is the number of frames lost
during the test (gaps in the load
received represent the lost frames).
This is the number of frames received
during the test which contain one or
more bits in error.
5-69

Advertisement

Table of Contents
loading

This manual is also suitable for:

N1735a