Connect the battery leads to the power supply

WARNING: Backup Battery
DO NOT CONNECT ANY BACK-UP BATTERY AT THIS TIME. Premature connection of the battery terminals may cause
damage to the control panel.
1.
Connect the battery wires that come with each circuit board kit to the power supply BATTERY INPUT
terminal block.
a)
Connect the black wire to the ground (GND) terminal.
b)
Connect the red wire to the +12V terminal.
c)
Make sure the battery wires are segregated at least ¼ inch away from all other input/output
wiring.
NOTE: Power Standby Level 1 for MET listed systems.

Wire the AC/DC power adapter to the power supply

WARNING: Power Adapter Connection
DO NOT CONNECT ANY POWER ADAPTER TO A SWITCHED OUTLET OR OTHERWISE CONTROLLED AC OUTLET.
DO NOT CONNECT ANY POWER ADAPTER TO THE 120 VAC OUTLET UNTIL ALL WIRING IS COMPLETED.
1.
The power adapter block(s) comes pre-wired with 10 feet of cable. If an extension is needed, use 18 AWG
wire (minimum grade) to connect to the 16.5VAC/19VDC POWER INPUT terminal block on the power supply
board, using terminals DC +/AC1 and DC -/AC2.
2.
To maintain MET compliance, the unit must be powered by a UL 294, UL 62368-1 or UL60950-1 Listed power
supply capable of supplying 16.5VAC, 3.03A, 60Hz or 19VDC, 2.63A to the power supply board.
© 2022 Brivo Systems LLC. All rights reserved.
Figure 11 - Connect Battery Leads to Power Supply