6.1. Proximity Switch Adjustment

1.
Disconnect screwdriver from air supply.
2.
Unscrew air connection.
3.
With the bit in the screwdriver, activate the push-to-start and
c o n t i n u e t o h o l d t h e s c r e w d r i v e r d o w n throughout
this procedure!
proximity switch
4.
Measure dimension „x" by means of a sliding caliper (see Picture 1)
5.
Adjust the sensor-front surface to dimension „x" less 0.3 mm to the
contact surface (see Picture 2) and than tighten it with nut.
6.
Assemble air connection.
nut