Sine/cosine interpolator with adjustable multiplication rate, for use with sine/cosine encoder systems (16 pages)
Summary of Contents for Motrona PU 210
Page 1
Operation Manual PU 210 Level Converter, Potential Separator and Direction Signal Decoder for Incremental Encoder Signals Signal inputs A, B, Z and /A, /B, /Z, adjustable to either RS422 format or TTL level or HTL (10-30V) level Signal outputs A, B, Z and /A, /B, /Z, likewise adjustable to either RS422 format or TTL level or HTL (10-30V) level ...
1. Safety Instructions and Responsibility 1.1. General Safety Instructions This operation manual is a significant component of the unit and includes important rules and hints about the installation, function and usage. Non-observance can result in damage and/or impairment of the functions to the unit or the machine or even in injury to persons using the equipment! Please read the following instructions carefully before operating the device and observe all safety and warning instructions! Keep the manual for later use.
For placement, wiring, environmental conditions as well as shielding and earthing/grounding of the supply lines the general standards of industrial automation industry and the specific shielding instructions of the manufacturer are valid. Please find all respective hints and rules www.motrona.com/download.html --> “[General EMC Rules for Wiring, Screening and Earthing]”.
2. Introduction This universal level converter, on the input side, can accept single channel and quadrature encoder signals with either RS422 format or TTL level or HTL (10-30V) level. Where the signal provides direction information, the direction may be defined by either an A/B-90° phase displacement, or by a static direction signal.
4. Switch settings The front DIL switches require a few settings depending on the signal levels and the mode of indicating the direction on inputs and outputs 4.1. Input characteristics You can set the desired input characteristics by switch DIL2, positions 6, 7 and 8 0=OFF DIL2 1=ON...
Position 1 affects input channel A Position 2 affects input channel B Position 3 affects input channel Z (marker pulse) OFF = Single-ended operation using HTL Level ON = Single-ended operation using TTL Level Ex factory all positions are set to OFF, i.e.
4.3. Definition of the direction of rotation The unit is designed to evaluate quadrature direction information (A/B, 2x90°) and static direction information as well. Furthermore it can convert the direction information from one format to the respective other format. Positions 3, 4 and 5 of switch DIL2 provide individual selection for input and output.
Need help?
Do you have a question about the PU 210 and is the answer not in the manual?
Questions and answers